Type | HF2420S60-100 | HF2430S60-100 | Parameter adjustable |
Battery input |
Battery type | Lead-acid or potassium batteries | √ |
Rated battery input voltage | 24V(minimum starting voltage 22V) | |
Maximum charging current of hybrid charging | 120A | 140A | √ |
Battery voltage range | 20VD-33VDCT 0.3Vdc(Voltage alarm/shutdown voltage/Overvoltage alarm/Overvoltage recovery... " | √ |
Solar input parameter |
Maximum PV open circuit voltage | 100Vdc | |
PV operating voltage range | 30-100Vdc | |
MPPT voltage range | 30-85Vdc | |
Maximum PV input current | 40A | |
Maximum PV input power | 1600W | |
Maximum PV charging current | 60A | √ |
Mains input parameters |
Maximum charging current of the mains | 60A | 80A | √ |
Rated input voltage | 220*230Vac | |
Input voltage range | UPS mains mode :(170Vac-280Vac)+2%; APL generator mode :(90Vac~280Vac)+2% | √ |
frequency | 50Hz/60Hz(Auto) | |
Mains charging efficiency | >95% | |
Conversion time (bypass vs. inverter) | 10ms | |
Maximum bypass overload current | 30A | |
Ac output parameter |
Output voltage waveform | Pure sine wave | |
Vac | 230Vac(200/208/220/240Vac) | √ |
VA | 2000(1750/1800/1900/2000) | 3000(2600/2700/2850/3000) | |
W | 2000(1750/1800/1900/2000) | 3000(2600/2700/2850/3000) | |
Peak power | 4000VA | 6000VA | |
On-load motor capability | 1HP | 2HP | |
Output frequency range(Hz) | 50Hz±0.3Hz/60Hz±0.3Hz | √ |
Maximum efficiency | >92% | |
No-load loss | Non-energy saving mode :≤50W; Energy saving mode :≤25W(required) | |