Good Price Portable Multi Parameter Medical Equipment ICU Patient Monitor

Min.Order: 2
Product origin: Hefei, Anhui, China
Infringement complaint: complaintComplaint
US$ 310

Description
Technical specification:
Application Range: Adult/Pediatric/Neonatal/Medicine/Surgery/ Operating Room/ICU/CCU
Display:
15" real color TFT screen
Resolution: 1024x768
One alarm indicator(yellow/red)
One working indicator(green)
One battery charge state indicator(green)
Three
modes in accordance with the alarm state

Power Requirements:
AC: 100 ~ 240V, 50Hz/60Hz
DC: Built-in rechargeable battery
Battery:
4000mA 1 1 . 1V lithium battery

2h operating after full charge(one piece) 5min operating after low battery alarm
Dimension and Weight:
Equipment:
360mm x162mm x321 mm ; 4 .5kgs
Package:
420mm x380mm x285mm; 7 .5kgs
Date Storage:
Trend diagram/table: 7x24h
NIBP review: 400 events
Wave review: 100min
Alarm review: 100 alarm events
Support drug concentration titration analysis
ST Segment:

ST Segment Range: -2 .0mV ~ +2 .0mV
Accuracy: 0.02mV

ECG:
5 Leads: RA , LA , LL , RL , V
Lead mode: I , II , III , aVR, aVL, aVF, V
Increase: ×250, ×500, ×1000, ×2000
Sensitivity: > 200 uV (Peak-to-peak value)
Input impedance: > 5 ( megohm )
Bandwidth: Surgery 1 ~ 20 Hz
Monitor 0 .5 ~ 40 Hz
Diagnostic 0 .05 ~ 130 Hz
CMRR 100dB
Polarization Voltage: ± 300mV
Baseline Recovering Time: After defibrillation< 3 seconds Signal Range: 8 mV ( Peak-to-peak value)
Calibrating Signal: 1mV, precision ±5%
Heart rate range: 15-380bmp
Heart rate accuracy:+/- 1%
RESP:

Method: RA-LL impedance
Resp Impedance range: 0 .3 ~ 3
Base Impedance range: 200 ~ 4000
Bandwidth: 0 . 1 ~ 2 .5Hz
Resp rate: Adult 0 ~ 120BrPM
Neonatal/Pediatric 0 ~ 150BrPM
Resolution: 1BrPM
Precision: ±2 BrPM
Asphyxia Alarm: 10~40 seconds

SpO2:
Range: 0 ~ 100%
Resolution: 1%
Precision: 70% ~ 100%: ±2 DIGIT
0% ~ 69%: ±no definition given

Pulse Rate:
Range: 20 ~ 300bpm
Resolution: 1bpm
Precision: ±3bpm
TEMP:

Channel: 2
Measure & alarm range: 0 ~ 50 C
Resolution: 0 . 1 C
Precision (no sensor): ±0 . 1 C

Standard accessories:
NIBP cuff & tube
ECG cable & electrodes
SpO2 sensor
TEMP probe
Lithium-ion battery
Power cable
Operator's manual

IBP:
Label ART, PA, CVP, RAP, LAP, ICP, P1, P2
Measuring and alarm range
ART: 0 ~ 300 mmHg
PA:-6 ~ 120 mmHg
CVP/RAP/LAP/ ICP - 10 ~ 40 mmHg
P1/P2 - 10 ~ 300 mmHg
Press Sensor
Sensitivity 5 uV/V/mmHg
Impedance 300-3000
Resolution: 1 mmHg
Accuracy: ±2% or ±1mmHg, which great
Actualization interval: about 1 Sec .

CO2:
Side/Main stream
Warm-up time: when the ambient temperature is 25 C, the carbon dioxide curve (capnogram) can be displayed within 20/ 15 seconds, and all the
specifications can be fulfilled within 2 minutes .
Measurement range: 0- 150mmHg , 0- 19 .7%,0-20kPa (at 760mmHg), atmospheric pressure provided by the host .
Resolution 0 . 1mmHg: 0-69mmHg
0 .25mmHg: 70- 150mmHg
Precision 0-40mmHg: ±2mmHg
41-70mmHg: ±5% (reading)
71- 100mmHg: ±8% (reading)
101- 150mmHg: ± 10% (reading)
Respiratory rate range 0- 150 BPM
Respiratory rate accuracy: ± 1 BPM



















Product Tag: