Electrical Characteristics | STC:AM1.5 1000W/m2 25°C NOCT : AM1.5 800W/m2 20°C Im/s Test uncertainty for Pmax: ±3% | ||
Module Type | WP-N72-590M | WP-N72-595M | WP-N72-600M |
Testing Condition | STC NOCT | STC NOCT | STC NOCT |
Maximum Power (Pmax/W) | 590 441 | 595 445 | 600 448 |
Open Circuit Voltage (Voc/V) | 52.51 49.30 | 52.66 49.44 | 52.81 49.58 |
Short Circuit Current (Isc/A) | 14.33 11.57 | 14.40 11.63 | 14.46 11.68 |
Voltage at Maximum Power (Vmp/V) | 44.36 40.48 | 44.51 40.62 | 44.66 40.75 |
Current at Maximum Power (Imp/A) | 13.31 10.90 | 13.37 10.97 | 13.44 11.00 |
Module Efficiency]%) | 22.8 | 23.0 | 23.2 |
Operating Parameters | Mechanical Loading | ||
Operational Temperature | -40oC~+85°C | Front Side Maximum Static Loading | 5400Pa |
Power Output Tolerance | 0-3% | Rear Side Maximum Static Loading | 2400Pa |
Voc and Isc Tolerance | ±3% | Hailstone Test | 5mm Hailstone at the speed of 23m/s |
Maximum System Voltage | DC1500V(IEC/U L) | ||
Maximum Series Fuse Rating | 25A | ||
Nominal Operating Cell Temperature | 45±2°C | Temperature Ratings (STC) | |
Protection Class | Class II | Temperature Coefficient of Isc | +0.050%/°C |
Fire Rating | U Ltypelor2 | Temperature Coefficient of Voc | -0.230%/°C |
IEC Class C | Temperature Coefficient of Pmax | -0.290%/°C |