Liquid Flow Meter Portable Ultrasonic Flowmeter of Handheld Ultrasonic Flow Sensor

Min.Order: 1
Product origin: Shanghai, China
Infringement complaint: complaintComplaint
US$ 760 ~ 800

Description
 
Product Description

ATUF portable ultrasonic flow meter is a type of portable instrument for non-invasive, quick flow and energy measurement with clamp-on technology for many types of piping. Portable ultrasonic flow meter support quickly verify the flow reading of another meter and to data log flow system values over an extended time period. The meter can be easily moved and installed in different pipes and convenient to carry site to site. The innovative design includes matched precision transducers and signal processing circuitry to accurately measure the flow of most liquids over a wide range of velocities. Its portability makes it an excellent choice for measuring flows throughout the plumbing infrastructure to verify sensor pump and valve performance.

Portable ultrasonic flow meter is easy to install which could reduce installation time and cost. With no pressure head loss, no moving parts which is very easy to maintain and replace. Support BTU function, could be used as a portable type BTU (energy) meter. Compared with other type of flow meters, portable type ultrasonic flow meter could be easily moved and convenient to carry in different sites.
Inaddition, it 
 is widely applied in oil industry, water treatment, pure water, chemical and etc.

 

 

Product Parameters
SizeDN25-DN1200mm (1"-48")
Accuracy±1% of measured value
Flow Range±0.03 ft/s ~±40 ft/s (±0.01 m/s ~ ±12 m/s)
FluidSingle medium liquid
Pipe MaterialCarbon steel, stainless steel, PVC and other compact material pipe
Power SupplyRechargeable Lithium Battery Power,3000mAh
(Continuous operation of main battery 16 hours).
OutputsAnalog output: 4~20mA, Max 750 Ω.
CommunicationRS485
Interval1 ~ 99999 seconds
TemperatureTransmitter: -40ºC~60ºC
Transducer: -40ºC~80ºC (standard), -40ºC~130ºC(optional)
HumidityUp to 99% RH,non-condensing
ProtectionTransmitter: NEMA13, IP54
Transducer: IP68
Cable5m
SD Card16G
 
Products Size

 

Model Selection
ATUFSpecificationXXXXX
Type of TransmitterUltrasonic Flow Meter1    
Ultrasonic Energy/Btu Meter function( RTD)2
Type of transducersClamp-on, IP68, -40ºC~ +80ºCD1
Clamp-on, IP68, -40ºC~ +130ºCD1U
Mounting trackSingle guide mounting type bracketST
Dual guides mounting type bracketDT
Cable length5m (standard)P5
XXmPXX
Temperature SensorWithout a pair of clamp on PT1000 sensorWT
With a pair of clamp on PT1000 sensor 9m
(BTU meter only)
WP

 

Installation Instructions


  • Installation Environment
It's better to install the flow meter indoors; if you have to install it outdoors, you should take measures to avoid direct sunlight or rainwater.
The flow meter shall be installed away from high temperature, thermal radiation from equipment or corrosive gas.
Ultrasonic flow meters can't be installed nearby motors, transformers or other power sources that are easy to cause electromagnet interference. DO NOT install ultrasonic flow meters nearby frequency converters or DO NOT connect it with the distributing cabinet of frequency converters to avoid interference.
In convenience for installation and maintenance, keep sufficient space around the flow meter.
  • Support of Flow meter
Avoid installing the flow meter on pipes with mechanical vibrations. If you have to install it there, DO take shock absorption measure. You could install a hose for transition, or set support points with absorbing pads on the pipe at 2DN in both upstream and downstream of the flow meter. Try not to install the flow meter on the longer overhead pipes because the sagging of pipes would cause leakage between the flow meter and the flanges. If you have to do it, you must set support points on the pipe at 2DN in both upstream and downstream of the flow meter.
  • Requirements on Liquid-receiving Material
The ultrasonic flow meter could measure single-medium liquid flow; The same medium could be divided into three specifications (low temperature, high temperature and superhigh temperature), different flow meters should be used for different temperatures.
  • Dangerous Conditions

You could select the flow meter with an explosion-proof housing, and intrinsic safety explosion-proof flow meter with intrinsic safety design circuit to ensure its safety and flame-retardant operation. Each flow meter should have a nameplate clearly identifying its certifications. Please DO install and use the flow meter according to the explosion-proof grade and protection grade as shown on the nameplate.

To ensure measurement accuracy of the flowmeter, try to satisfy the following requirements on the length of straight pipe sections installed nearby the flowmeter: upstream >20D, downstream>10D.