gas |
Measuring range
| resolution | Operating temperature |
H2S (1S) | 0 -200ppm | 0.1 ppm | -40to+60°C |
CO (1S) | 0 - 2000ppm | 1 ppm | -40to+60°C |
O2(1S) | 0 - 30%v/v | 0.1% v/v | -40to+60°C |
CL2(4S) | 0 - 50ppm | 0.1 ppm | -20to+40°C |
CO2(1S) | 0-50000ppm | 100ppm | -20to+60°C |
CLO2(4S) | 0 - 1 ppm | 0.01ppm | -20to+40°C |
CO-H (4S) | 0 - 2000ppm | 0.5 ppm | -30to+50°C |
ETO (4S) | 0 - 100ppm | 0.1 ppm | -30to+50°C |
H2(4S) | 0 - 1000ppm | 2 ppm | -20to+50°C |
H2S(extended range)(4S) | 0 - 500ppm | 0.1 ppm | -40to+50°C |
HCN (4S) | 0 - 100ppm | 0.1 ppm | -30to+50°C |
NH3(4S) | 0 - 100ppm | 1 ppm | -20to+40°C |
NH3((extended range)(4S) | 0-1000ppm | 1 ppm | -20to+40°C |
NO (4S) | 0 - 250ppm | 0.2 ppm | -30to+50°C |
NO2(4S) | 0 - 100ppm | 0.1 ppm | -20to+50°C |
O3(4S) | 0 - 1 ppm | 0.01ppm | -20to+40°C |
PH3(4S) | 0-5ppm | 0.1 ppm | -20to+50°C |
SO2(4S) | 0 - 100ppm | 0.1 ppm | -30to+50°C |
H2S (4S)* | 0 - 100ppm | 0.1 ppm | -20to+50°C |
CO (4S)* | 0 - 1000ppm | 1 ppm | -20to+50°C |
O2 (4S)* | 0 - 30% v/v | %0.1 v/v | -20to+50°C |
Instrument Specifications | |
Battery | Replaceable non-rechargeable lithium battery |
running time | 12 months (1 series O2 6 months) |
Alarm method | Visible, vibration, sound (95dB) |
alarm typealarm | Low report, high report, TWA, STEL, low battery, sensor failure, non-compliance alarm |
user options | • Change the alarm set point |
Self-check | Check the integrity of the sensor, circuit board, battery condition and sound/visual alarm at start-up, battery (uninterruptible) |
calibration | Manual or IntelliDox instrument automatic management platform |
wireless | Wireless version: Bluetooth Low Energy (BLE), supports Safety Communicator app |
Certification and Licensing | •CSA certification:Class I, Division 1, Group A,B,C,D T4; Class I, Zone 0, AEx/Ex ia IIC T4 Ga • ATEX certification: II 1G I M1 / Ex ia IIC T4 Ga; Ex ia I Ma •IECEx certification: Ex ia IIC T4 Ga/ Ex ia I Ma • China explosion-proof certification: Ex ia IIC T4 Ga • China CPA certification |
EMI/RFI | Meets the requirements of the EU Electromagnetic Compatibility (EMC) Directive 2014/30/EU |
Protection class | IP66/68 |
language | Multiple operating languages including Chinese and English |
humidity | 0% - 95% relative humidity (non-condensing) |
size | • 7.0 x 6.7x 3.6 cm (Series 1 sensor models) • 7.0 x 6.7x 4.1 cm (Series 4 sensor models) |
weight | 103 to 116 g, depending on the type of sensor installed |
quality assurance | 1 year warranty on detector and sensor (excluding batteries) |