Fully Autonomous System Ese Lightning Rod for Lightning Protection of New Generation Weather Radar Stations

Min.Order: 1
Product origin: Zhengzhou, Henan, China
Infringement complaint: complaintComplaint
US$ 269 ~ 299

Description
Small and medium-sized radar vehicles or special vehicles have higher requirements for lightning protection equipment to prevent lightning strikes from causing damage to precision equipment. The ESE air-termination device has passed the lightning test of the WHVRI High Voltage Research Institute. The maximum peak current test is N/100KA, and it can generate electricity 60microsecond in advance. Due to its light weight and good high pressure resistance, it is recommended to be used in places with high requirements.

 

 

YBT-YFD60 Lightning Rod Protection Radius(NFC 17-102)
categoryClass 1 protectionClass 2 protectionClass 3 protection
model183145601830456018304560
Height(m)Protection radius(m)
2141925321925324022283644
2212838482938485933425765
4283851643850657844577287
53548637949638197557189107
63548637949648197567290107
83649647951658298587391108
103749647952668399607592109
1538506580556985101647895111
2038506580587186102678197113
45385065806375901057789104119
60385065806375901057890105120

 

 

Equipped with energy storage components, it has the ability to trigger the upward leader.
Optimize the head radius to reduce the corona effect and ensure the normal operation of the pulse device.

LIGHTNING ROD CHARACTERISTICS

1.The electronic components are completely wrapped in epoxy resin to prevent internal electronic components from being damaged by lightning strikes.
2.No radioactive elements, safe and reliable; stainless steel material,corrosion-resistant,beautifulappearance.
3.Accurately judge the timing of discharge,make lightning strikes more accurate, and reduce the probability that the lightning strike point falls on a non-lightning rod body.
4.Fully active system, self-activating.

LIGHTNING ROD INSTALLATION
1.Determine building lightning protection based on the area and height of the protected building,the number oflightning days in the location, the geographical environment correction coefficient, the nature ofthe building's use,etc.
2.The down conductors (down conductors) should be electrically connected to the main steel bars of the building,or two or more down conductors (down conductors) should be made as required.
3.The down conductor (down conductor) should be disconnected and insulated on the ground nearby.
4.The grounding body, grounding resistance, and lightning protection ground network should be implemented in accordance with the lightning protection standard GB50057-2010.

 

 

 

 