Product Description

6ka circuit breaker one series RCBO&MCB&RCCB assembly  :


1.RCBO is mainly used in AC 50Hz(60Hz), rated voltage 230/400V, rated current 6A to 63A low voltage terminal distribution system. RCBO is equal with MCB+RCD function; It is used for electric shock protection and human indirect contact protection, electric equipment protection when human body touching electricity or electric network leak current exceeds stipulated value,and over load and short circuit protection ; It can also be a non-frequency operator in the circuit, wildly used in the residential and commercial district. It complies with standard of IEC61009-1.

2.MCB is used in AC50/60Hz, rated voltage of 230V3, 4 poles 400V, rated current to 63A for overload and short-circuit protection as well as for unfrequented switching under normal case.It is used extensively for industry, commercial and household.This product conform to IEC60898 standard.

3.RCCB is in conformity with the standards of IEC61008.It can cut off the fault circuit immediately on the occasion of shock hazard or earth leakage of trunkline.Thus it is suitable to avoid the shock hazard and fire caused by earth leakage.It can be used in circuits up to single phase 240V,three phase 415V,50 or 60Hz.

 



Roduct Over View:

1. Provide protection against earth fault/leakage current and function of isolation

2. High short-circuit current withstand capacity3. Applicable to terminal and pin/fork type busbar connection

5. Automatically disconnect the circuit when earth fault/leakage current occurs and exceeds the rated sensitivity

6. Independent of power supply and line voltage, and free from external interference, voltage fluctuation. 

Specifications

RCBO

 Standard UnitIEC/EN 61009-1

Electrical

features

Mode  Electro-magnetic type ,electronic type
Type(wave form of the earth leakage sensed) A, AC
Thermo-magnetic release characteristic B,C,D
Rated current lnA6,10,16,20,25,32,40
PolesP1P+N, 3P+N
Rated voltage UeVAC 230, 400
Rated sensitivity I△nA0.01, 0.03, 0.1, 0.3, 0.5
Rated residual making and breaking capacity l△mA500
Rated short-circuit capacity IcnA6000
Break time under I△nS≤0.1
Rated frequencyHz50/60
Rated impulsewithstand voltage(1.2/50)UimpV4000
Dielectric test voltage at ind.Freq for 1minkV2
Insulation voltage UiV250
Pollution degree 2

Mechanical

features

Electrical life 4000
Mechanical life 10000
Fault current Indicator YES

Protection degree

 

IP20

Ambient temperature

(with daily average≤35ºC)

ºC

-5~+40(Special application please refer to

temperature compensation correction)

Storage temperatureºC-25~+70
InstallationTerminal connection type Cable/Pin-type busbar/U-type busbar
Terminal size top/bottom for cablemm225
AWG18-5
Terminal size top/bottom for busbarmm225
AWG18-3
Mounting On DIN rail EN 60715(35mm)by means of fast clip device
Connection From top

MCB
 
ModelMCB
StandardIEC60898
Pole1P,2P,3P,4P
Tripping CurveB,C,D
Rated Short-circuit capacity(Icn)3KA,4.5KA,6KA,10KA
Rated Current(In)1,2,4,6,10,16,20,25,32,40,50,63A
Rated Voltage(Un)AC230(240)/400(415)V
Magnetic releases B curve: between 3and 5 In
 
C curve: between 5and 10In
 
D curve: between 10 and 14In
 
Electro-mechanical enduranceover 6000 cyclesC


RCCB
 
 StandardUnitIEC/EN 61008-1
Electrical
Feature
Type(wave form of the earth leakage sensed) AC,A 
Rated current InA16,25,32,40,63 
PolesP2,4
Rated voltage UeV230/400
Rated sensitivity I nA0.01,0.03,0.1,0.3
Insulation voltage UiV500
Rated residual making andA630
breaking capacity I m  
Short-circuit current I cA4500/6000
SCPD fuseA6000
Break time under I ns<0.1
Rated frequencyHz50/60
Pollution degree 2
MechanicaI
features
Electrical lifet4000
MechanicaI Iifet20000
Fault current indicator Yes
Protection degree IP20
Ambient temperatureCFrom -25C untill 40C
(with daily average 35 )  
Storage temperatureCFrom -25C untill 70C

 
FAQ

Q 1. what's the payment term?   

A. We accept TT,30% deposit and 70% balance agaisnt copy of BL
Q 2. how's the delivery time ? 
A. usually it will take about 25 days for production
Q 3. tell me the standard of package?  
A. Normally are cartons, but also we can pack it according to your requirement.
Q 4.Would you accept to use our logo ? 
A.If you have good quantity,it absolute no problem to do OEM.
Q5. Can i take some samples?
A: Yes, we support to take samples before place the order. Just feel free to contact with us if you have any requirements.
Q6. Are you original Factory?
A: Yes, we have our own factory .
Q7. How can you make sure the quality of the products?
A: We will accord to international quality standards to inspect every item before leaving our factory.Contact  us

Thanks for your reading.If any product meets your need.Welcome to send us an email or by Wechat and WhatsApp.We are sure your any information can be attentioned without any delay. 

Product Tag:
Related categories:
Scroll to Top