Hxf4 Type Fire Block Breathing Valve with Exhalation Nozzle

Min.Order: 1
Product origin: Wenzhou, Zhejiang, China
Infringement complaint: complaintComplaint
US$ 15

Description

HX-4, HXF-4 with exhalation nozzle (fire resistance) breathing valve introduction

HX-4, HXF-4 with exhalation nozzle (fire resistance) breathing valve is installed on the top of the indoor storage tank nozzle breathing, it can automatically adjust the oil storage tank internal and external pressure difference, its performance is stable, in line with the Ministry of petroleum industry SY7511-87 standard.

HX-4, HXF-4 with exhalation nozzle (fire resistance) breathing valve application range

It is suitable for storage of Class A oil with flash point below 28ºC and Class B oil with flash point below 60ºC, such as gasoline, benzene, kerosene, light wood, thick oil and other oil products and chemical products with the same nature storage tank.

HX-4, HXF-4 with exhalation nozzle (fire resistance) breathing valve disc operating pressure

GradesOperating pressure
Class A+355Pa (36mm water column) -295Pa (30mm water column)
Grade B+980Pa (100mm water column) -295Pa (30mm water column)
Grade C+1765Pa(180mm water column) -295Pa (30mm water column)
Grade DAs required by user (other pressure levels)

HX-4, HXF-4 with exhalation nozzle (fire resistance) breather valve maintenance and maintenance

In order to achieve the safe use of the performance of the HX-4 and HXF-4 breathing valves with exhalation nozzle (fire resistance), the breathing valves should be inspected and maintained regularly:
1. Check whether the pressure valve disc and the vacuum valve disc are flexible, and whether there is damage in the contact of the guide rod and the valve seal ring.
2. When reinstalling the pressure disc and vacuum disc, the contact surface should be tight and the guide rod should be raised and lowered flexibly.
3. When starting the new breathing valve, the shockproof objects between the valve disks must be cleaned, and the valve should be installed vertically.

HX series breathing valve code description

The breathing valve code is HX, HXF is the fire resistance breathing valve code;
The type of breathing valve is classified by whether the suction and exhalation outlets are connected, a total of 8 kinds, as follows:
ModelTypeModel numberType
HX1Breather valveHXF1Fire stop breather valve
HX2With double nozzle breathing valveHXF2Fire block breather valve with double nozzle
HX3Breather valve with suction nozzleHXF3Fire blocking breather valve with suction nozzle
HX4Breather valve with exhalation nozzleHXF4Fire blocking breather valve with exhalation nozzle
HX5Single call valveHXF5Fire stop single call valve
HX6Single suction valveHXF6Fire blocking single suction valve
HX7Exhalation valve with nozzleHXF7Fire blocking exhalation valve with nozzle
HX8Suction valve with nozzleHXF8Fire retardant suction valve with nozzle

HX-4, HXF-4 with exhalation nozzle fire retardant breathing valve (DN50-250) structure and size

 
DN5080100150200250
H330380420490630650
H (with fire block)350400450520650690
L275345390460570630