Advantages: Small size and light weight with built-in control and protection circuits High efficiency up to 45% have sufficient power capacity to ensure high reliability Output power can from 20watts to 250watts Support to add Sweep Generator or Wide-band Noise Generator or Digital Generator as jammer module Customized Service screen printing customized contents can be customized,such as logo, model etc |
Item | Parameters | Renark | ||||
Frequency range | 20-88/134-174/300-350/400-500/925-960/1805-1880/2110-2175/2400-2500/5700-5900 or any 5-300MHz band in 20-6000MHz | |||||
input Power | ≤10dBm or customized | |||||
Output Power@CW | 100watts | |||||
Gain | 55dB | |||||
Gain Flatness(dB) | ≤1dB if frequency range<100MHz | |||||
≤1.5dB if frequency range<200MHz | ||||||
≤2dB if frequency range<300MHz | ||||||
VSWR | <1.5 | |||||
Gain Adjustment range | ≥31dB | |||||
Efficiency | ≥35% | |||||
RF connectors | SMA(F)/N female or customized | |||||
Monitoring interface | DB9 | |||||
working voltage | 28VDC | |||||
Operating temperature | -35~+65 degree | |||||
Storage temperature | -55 to +85 degree | |||||
Protection | VSWR protection | If VSWR exceeds 3:1, an alarm is generated and PA will off if PA exceeds 5:1 | all threshold can be cusmotized | |||
Temperature protection | If temperature exceeds 60 ºC, generates an alarm and reach 80ºC, turn off the amplifier,until the temperature returns to below 55 ºC, re-open PA | |||||
provide Forward power voltage detection,Reverse power voltage detection,Temprature voltage detection and Enable | ||||||
support to monitor output power, Reverse power, VSWR value or temperature value via RS-232 port |
Some PA test report:
100watts 3000-3500MHz | 100watts 950-1250MHz |