Kolo High-Frequency Customized Linear Array Transducer

Min.Order: 1
Product origin: Suzhou, Jiangsu, China
Infringement complaint: complaintComplaint
US$ 10000 ~ 30000

Description
L15-5
The L15-5 linear array transducer, with a center frequency of 10MHz, is designed for Vascular, Small Parts and deep MSK imaging.
Center Frequency10.0 MHz
Bandwidth85%
Number of Elements192
Element Spacing0.20 mm
Elevation Focus18 mm
Elevation Aperture3.25 mm
Maximum AC Voltage120V
Bias DC Input+3.3V~+10.5V


 
L30-14
The L30-14 linear array transducer which is centered at 22MHz,can be used primarily for Neonatal, Pediatric, and MSK applications.
Center Frequency22.0 MHz
Bandwidth70%
Number of Elements256
Element Spacing0.082 mm
Elevation Focus10.8 mm
Elevation Aperture2.25 mm
Maximum AC Voltage120V
Bias DC Input+3.3V~+10.5V


 
L22-8
The L22-8 linear array transducer is the workhorse for MSK and Small Parts Imaging. Centered at 15MHz, this transducer has better spatial resolution with equal penetration when compared with PZT transducers.
Center Frequency15.0 MHz
Bandwidth80%
Number of Elements256
Element Spacing0.108 mm
Elevation Focus15 mm
Elevation Aperture2.5 mm
Maximum AC Voltage120V
Bias DC Input+3.3V~+10.5V


 
L38-22
The L38-22 with a center frequency of 30MHz allows for true superficial imaging in the emerging applications of Dermatology. Additional applications include tendons, nerves, and joints of the Hands, Wrist, and Feet.
Center Frequency30.0 MHz
Bandwidth60%
Number of Elements256
Element Spacing0.069 mm
Elevation Focus8.0 mm
Elevation Aperture1.8 mm
Maximum AC Voltage120V
Bias DC Input+3.3V~+10.5V


 
M17-4
A 1D transducer array has single elements with fixed size and focus in the elevational dimension. A SiliconMatrixTM Array has multiple elements in both the azimuthal and elevational dimensions,enabling a variable aperture size with multiple focal points to generate a narrow elevation beam throughout the entire imaging field resulting in unparalled image quality to depth.
Center Frequency8.0-10.0 MHz
Bandwidth90-110%
Number of Elements192
Number of Sub-elements3
Element Spacing0.21 mm
Elevation Focus30.0 mm
Elevation Aperture3.0+1.5×2 mm
Maximum AC Voltage120V
Bias DC Input+3.3V~+10.5V


 
Customized Transducer List
CategoryCentral FrequencyElementsApplicationMain Products
Linear Transducers7.5-30MHz128-384ENeonatology & Pediatrics
Musculoskeletal
Dermatology
Small Parts
Vascular
Breast
...
Intraoperative
Laparoscopy
Photoacoustic
imaging
...
L38-22
L30-14
L22-8
L15-5
Matrix Transducers7.5-15MHz128-256EM17-4
Product Tag:
Related categories:
Scroll to Top