Description
Why Venttech?
1. Provide non-standard product customization and able to develop new products.
2. Set up a high-tech product research and development center, 16 professional technical R&D experts, the team includes various experts in mechanical engineering, automatic control, system design, cryogenic engineering, testing, etc. And maintain close cooperation with Xi'an Jiaotong University and other Chinese higher education institutions for a long time.
3. At present, the production capacity can reach 1 million pcs a year.
Product
1. Provide non-standard product customization.
2. Products are compatible with all common refrigerants (R410A, R134a, R22, R407C, R404).
3. Max. production size: 6000*1200mm(L*H).
4. Can offer L, U or C shape bending products.
5. Products can be with e-coating, epoxy, powder coating or normal painting treatment. Use
MCHE is mainly used in heat exchange applications such as household air conditioners, commercial air conditioners, auto air conditioners, freezing and refrigeration system, computer room air conditioners, heat pumps, chillers, laundry dryers, etc Quality
1. Production 100% pass water or helium inspection test, ensure there is no leak products.
2. ISO 9001:2015 Service
1. Offer MCHE drawing design service.
2. Respond to inquiries within 24 hours on weekdays and 48 hours on holidays
3. Product lead time normally is about 30 days.
Advantage
1. High heat exchange efficiency.
2. High thermal response rate and good controllability.
3. Low noise, stable operation.,
4. Good pressure bearing capacity.
5. Corrosion resisting.
6. Cost saving, low material consumption under the same heat exchange requirements.
Condenser
Flat tube specs: 12mm, 16mm, 18mm, 20mm, 25.4mm, 32mm and 36mm
Header tube specs: 16mm, 20mm, 22mm, 25mm, 30mm and 40mm
Technology
Integral brazing, low thermal contact resistance, can improve the heat transfer performance perfectly, AL-AL structure, without electric potential difference, high corrosion resistance.
Smaller diameter, many tube holes and large internal surface intensify unit capacity as per volume.
Small cross sectional area, low air flow resistance, small eddy area, low noise.
Parallel arrangement of flat tubes enlarge refrigerant circulation area
Adjust the position and baffles to adapt to the refrigerant phase transition and optimize heat transfer and pressure drop.
The structure effectively breaks air thermal boundary layer, reduce heat exchanging resistance.
Waving path makes the contact longer to intensify heat exchanging.
Application:Coach air-con | Heavy truck air-con |
|
|
Transport refrigeration | Food cooling |
|
|
Dryer | Tower crane air conditioner |
|
|
Computer room air conditioning | Communication cabinet |
|
|
Commercial air conditioning(e.g. chiller) | Cold room condensing unit |
|
|
Factory