Customized 4.8V AA Ni-MH Rechargeable Battery Pack
Description | Unit | Specification | Conditions | |
Nominal Voltage | V/ Cell | 1.2 | Unit cell | |
Nominal Capacity | mAh | 1800 | Standard Charge/Discharge | |
Standard Charge | mA | 180(0.1C) | Ambient Temperature: Ta= 20±5ºC | |
Hour | 16 | |||
Trickle Charge | (0.03C)~(0.05C) | Ta = 0~45ºC | ||
Standard discharge/ | mA | 360(0.2C) | Ambient Temperature: Ta = 20±5ºC Humidity Max:85% | |
Discharge Cut-off Voltage / | V/ Cell | 1.0 | ||
Operating temperature range/ | ºC | 0~45ºC | Humidity Max :85% | |
Storage Temperature | ºC | -20~35ºC | 1 year | Fully charged state,Humidity,Max.60% |
0~60ºC | 1 week | Fully charged state,Humidity,Max.80% | ||
Typical Weight/ | g | Approx.27.0 |
Test | Unit | Specification | Other Condition | Remarks |
Capacity | mAh | ≥1800 | Standard Charge Discharge | up to 3 cycles are allowed |
Open Circuit Voltage(OCV) | V/Cell | ≥1.25 | Within l hour after standard Charge | |
Internal Impedance | mΩ/ Cel | ≤35 | Upon fully charge(lKHz) | |
High Rate Discharge(0.5C) | minute | ≥96 | Standard Charge, l hour rest Before Discharge by 0.5C to 1.0 V | up to 3 cycles are allowed |
Overcharge | No leakage nor explosion | 0.1C Charge14 days | ||
Charge Retention | mAh | ≥1080(60%) | Standard Charge, Storage:7 day rest at 45Ambient Temperature,Standard Discharge | |
IEC Cycle Life | Cycle | ≥500 | IEC61951-2(2003)7.4.1.1 | |
Leakage Test | No leakage nor deformation | Fully charged at 0.5C for 2.5 hour stand for 14 days. | ||
Security Test | No explosion,but leakage or deformation is allowed | Charge the cell 0.1C 16hrs, Then≤100 mΩImpedance short circuit for 1hour | Ambient Temperature/ :T=20±5ºC | |
Impact Resistance | Change of voltage should be under 0.02V/ Cell Change of impedance should be under 5 mΩ | Charge the cell 0.1C 16hrs Then leave for 1~4hrs,check battery before/after dropped,Height 50cm Wooden board (thickness 30mm) Direction not specified,3 times. | Ambient Temperature/ :T=20±5ºC | |
Vibration Resistance | Change of voltage should be under 0.02V/cell,Change of impedance should be under 5 milliohm/cell | Charge the battery 0.1C 16hrs, then leave for 24hrs,check Battery before/after vibration, Amplitude 1.5mm Vibration 3000CPM, Any direction for 60mins. | Ambient Temperature/ :T=20±5ºC |
1.We offer OEM/ODM services with our professional team.