Rpm65/65c Power Quality Analyser Network Analyzer Power Meter Multi Meter

Min.Order: 1
Product origin: Foshan, Guangdong, China
Infringement complaint: complaintComplaint
US$ 140 ~ 404

Description

Product Description


*T rue RMS measurements (512 samples/cycle)
For single-phase, two-phase, three-phase system
   Measurements: VL-L, VL-N, I, In, Cos , Pf, Hz, W, ∑W, Va, ∑Va, Var, ∑Var, import Kwh, export Kwh,import Kvarh, export Kvarh, V-THD,
   I-THD,1-63th harmonic, system running hours, % voltage unbalance, %current unbalance, % system load, total frequency.
3 voltage and 4 current input (Measure or calculate the neutral current)
Voltage Input: 0-690Vac, Current input: 1 or 5A CT selective
% system load and system running hours
Detects CT wiring errors
Maximum, minimum and demand for U, I, P, Q, S in hours, days, months
Real time clock with integrated backup rechargeable battery
4 quadrants energy measurement , 4 tariffe energy measurement and  monthly energy calculation
2 pulse output and RS485 communication: Modbus RTU
Waveforms and phase diagram for voltage, current
Alarm event log
Micro SD(support 32GB) for data logger
Data recorded in standard excel file formats for further EN50160 analysis
English, Chinese (traditional & simplied)
Moduel function options (only one can be selected)
   - 7 digital input +2 relay output(remote or alarm)(Standard)
   - 7 digital input +2 analog output(4-20mA) for V1,V2,V3,V12,V23,V31,I1,I2,I3 (option)
   - Ethernet (Modbus TCP), Web server+2 digital input +2 relay output(remote or alarm) (option)
   - LoRa wireless (Private protocol)+2 digital input+2 relay output (remote or alarm)(option) 
   - RS-485 interface (Modbus RTU)+2 digital input+2 relay output (remote or alarm)(option)
   - WIFI wireless +2 digital input +2 relay output(remote or alarm) (option)

Product Parameters

Auxiliary Supply
Operating voltage (Un)85···265 VAC 50/60Hz 10W / 100-285VDC/24-48VDC(depend on order)
Power consumption4VA max
Measurement input
Voltage inputs for direct connection:Phase-neutral(L-N): max 400V RMS CAT III
Input impedance(for direct voltage inputs):>4MΩ
CT inputs:max 5.5A RMS
CT inputs overload capacity:max 10A
CT inputs Self-consumption :<0.2VA
Accuracy
Three phase voltage:± 0.2%
Currents:± 0.2%
Powers:± 0.5%
Powers factor:± 0.5%
Frequency:± 0.02%
Harmonics:± 1%
Active energy:Class 0.5S
Reactive energy:Class 0.5S
Insulation
Insulation voltage
3kV for 1 min., 50Hz
Display
Display type
RPM65: 3.2inch 240x160 pix, RPM65C: LCD3.5" 320x240 color TFT LCD
I/O
Digital inputs:
Active dry contact
Digital outputs:
2 Relay N/O 220VAC 5A
Analog outputs:
4-20mADC / max load 500Ω
Pulse output:
24-30VDC Max.50mA, Min. 50msec pulse width
Memory 
Recording memory:
max 32 GB SD (TF)
Communication
Ethernet port:
Auto MDIX Rj45 10/100 Base Ethernet
RS-485 port:
1 optoisolated, 4800-57600
Protocols:
HTTP, HTTPS, Modbus RTU/TCP
Environmental conditions
Opterating temperature:
-10···+55°C
Storage temperature:
-25···+75°C
Relative humidity:
95% max without condensing
Altitude:
max 2000m AMSL
Installation & use:
Internal
Mechanical characteristics
Mounting:
Panel mount 96x96mm(The panel cut-size 92*92mm)
Size:
Front(WXH)96x96mm, Rear (HxD) 90x70mm
Degree of protection:
IP40(optional IP54) on front, IP20 housing and terminals
Weight:
400g
Standard compliance
reference standard:
IEC61010-1; IEC61557-1;IEC61557-12; IEC61326-1;IEC62053-21;
IEC62053-22; IEC62053-31; IEC60068-2-1; IEC60068-2-30;
IEC60364-5-52; IEC61000-3-2; IEC61000-3-3; IEC61000-4-2;
IEC61000-4-3; IEC61000-4-4; IEC61000-4-5; IEC61000-4-6;
IEC61000-4-8; IEC61000-4-11; IEC61000-4-30