1. Gel & Clot Activator Tube Gel and clot activator tube is used for blood serum biochemistry, immunology and drug testing, etc. There uniformly sprays the coagulant on the surface inside the tube, which will greatly shorten the clotting time. As the imported separation gel from Japan is pure substance, very stable in physicochemical property, it can well stand high-temperature so that the gel will maintain a stable status during the storage and transportation process. The gel will get solidified after centrifugation and completely separate serum from fibrin cells just like a parclose, which effectively prevents the substance exchange between blood serum and cells. Serum collection efficiency is improved and high-quality serum will be obtained, thus it comes to more authentic testing result. Keep the serum stable for more than 48 hours, no obvious change will happen on its biochemical features and chemical compositions, then the tube could be directly used in sampling analyzers. - Time for complete clot retraction: 20-25min - Centrifugation speed: 3500-4000r/m - Centrifugation time: 5min - Recommended storage temperature: 4-25ºC |
2.Clot Activator Tube Clot activator tube is used in the blood collection for biochemistry and immunology in medical inspection. It is suitable for wide range of operating temperature. With special treatment, the tube inner surface is very smooth where high-quality coagulant sprays uniformly. The blood sample will completely contact with coagulant and clot within 5-8min. High-quality serum thus is obtained by later centrifugation, free from the cracking of blood corpuscle, hemolysis, separation of fibrin protein, etc. Hence the serum can meet the requirements of fast clinic and emergency serum test. - Time for complete clot retraction: 20-25min - Centrifugation speed: 3500-4000r/m - Centrifugation time: 5min - Recommended storage temperature: 4-25ºC |
3.EDTA Tube EDTA tube is widely used in clinical haematology, cross matching, blood grouping as well as various kinds of blood cell test instruments. It offers a comprehensive protection for blood cell, especially for protecting the blood platelet, so that it can effectively stop the gathering of blood platelet and makes the form and volume of blood cell uninfluenced within a long time. Excellent outfits with super-minute technique can spray additive uniformly on the inner surface of the tube, thus blood specimen can completely mix with the additive. EDTA anticoagulant plasma is used for biological assay of pathogenic microorganism, parasite and bacterial molecule, etc. |
4.DNA Tube 1.The blood RNA/DNA tube prefilled with special reagent to quickly protect the RNA/DNA of specimens not to be degraded 2.The blood specimens can be stored for 3 days at 18-25°c, stored for 5 days at 2-8°c, keep stable for at least 50 months at -20°c to -70°c 3.Easy to use, only invert the blood RNA/DNA tube at 8 times after collection can intensive mixing of blood 4.Apply to fresh blood of humans and mammals, not suitable for timeworn blood & congealing blood as well as blood of poultry & other animals 5.Standardized collection, storage and transport of whole blood RNA/DNA detection specimens 6.Inner wall of the tube is special processing without RNase,DNase, ensure the primariness of nucleic acid detection specimens 7.Conducive to mass and rapid extraction of specimens, improve working efficiency of the laboratory |
5.ESR Tube Ø13×75mm ESR Tube is specially used in blood collection and anticoagulation for Automated Erythrocyte Sedimentation Rate Analyzers sedimentation rate test with the mixing ratio of 1 part sodium citrate to 4 parts blood, by Westergren method. |
6.Glucose Tube Glucose tube is used in blood collection for the test such as blood sugar, sugar tolerance, erythrocyte electrophoresis, anti-alkali hemoglobin and lactate. The added Sodium Fluoride effectively prevents metabolism of blood sugar and Sodium Heparin successfully solves the hemolysis. Thus, the original status of blood will last for long time and guarantee stable testing data of blood sugar within 72 hours. Optional additive is Sodium Fluoride+Sodium Heparin, Sodium Fluoride+ EDTA.K2, Sodium Fluoride+EDTA.Na2. - Centrifugation speed: 3500-4000 r/m - Centrifugation time: 5min - Recommended storage temperature: 4-25 ºC |
7.Heparin Tube Heparin tube is used in blood collection for the test of clinical plasma, emergency biochemistry and blood rheology, etc. With little interference on blood compositions and no influence upon the erythrocyte size, it won't cause hemolysis. Besides, it has the features of quick plasma separation and wide range of operating temperature as well as high compatibility with serum index. |
8.PT Tube PT tube is used for blood coagulation test and applicable to fibrinolytic system(PT,TT, APTT and fibrinogen, etc. The mixing ratio is 1 part citrate to 9 parts blood. Accurate ratio can guarantee effectiveness of the testing result and avoid misdiagnosis. As the sodium citrate has very little toxicity, it is also used for blood storage. Do draw sufficient blood volume to ensure accurate testing result. PT tube with double-deck is with little dead space, Which can be used to monitor the test of vWF, F,platelet functions, Heparin therapy. |
Cap color | Clinical application | Volume | Specimen | Additive | |
Red | Serum biochemistry | 2/3/4/5ml | Serum | None (A silicone coating on the interior walls reduces adherence of the red cells to tube walls) | |
Yellow | Quick serum biochemistry test | 2/3/4/5ml | Serum | Separation Gel and Clot Activator (A silicone coating on the interior walls reduces adherence of the red cells to tube walls) | |
Orange | Quick serum biochemistry test | 2/3/4/5ml | Serum | Clot Activator : fibrin ferment (A silicone coating on the interior walls reduces adherence of the red cells to tube walls) | |
Blue | Blood coagulation test | 2/3/4/5ml | Plasma | Anticoagulant : Blood should be 9 times than sodium citrate | |
Grey | Blood glucose test | 2/3/4/5ml | Plasma | Anticoagulant : EDTA, Sodium Fluoride | |
Green | Blood rheologytest | 2/3/4/5ml | Plasma | Anticoagulant : Lithium heparin or Sodium heparin | |
Aqua | Quick plasma biochemistry test | 2/3/4/5ml | Plasma | Separation gel, Lithium heparin | |
White | Nucleic acid detection test | 2/3/4/5ml | Plasma | Separation gel, EDTA | |
Purple | Whole blood test | 1.8/2.7/3.6ml | Whole Blood | Anticoagulant : EDTA-2K or EDTA-3K | |
Black | ESR | 2/3/4/5ml | Whole Blood | Anticoagulant : Blood should be 4 times than sodium citrate |