TH8030 Calibration System for 
Permanent  Magnet Magnetic Measuring Instrument

1. Summary
TH8030 is a system dedicated to calibrating magnetic properties measuring instruments of permanent magnet materials, including a measuring host and precision excitation power supply. It can realize the calibration of Tesla meter, flux meter, electromagnet magnetic field non-uniformity, coil constant, magnetic characteristic parameters and other items of the magnetometer being calibrated.

2. Features
  1. Equipped with a precision DC excitation power supply with an accuracy of class 0.005.
  2. The host machine has a built-in precision magnetic flux meter with an accuracy of class 0.05.
  3. The host machine has a built-in precision magnetometer with an accuracy of class 0.05.
  4. The host has a built-in volt-second magnetic flux calibrator with an accuracy of class 0.02.
  5. The host machine has a built-in precision temperature and humidity meter to measure the temperature and humidity of the on-site environment.
  6. The host computer has a built-in three-axis fluxgate magnetometer to measure the on-site environmental magnetic field.
  7. Equipped with an intelligent probe positioning device to facilitate calibration of electromagnet magnetic field non-uniformity.
  8. Communication interfaces: RS232, USB, LAN
  9. The system adopts modular integrated design.
  10. Equipped with specialized calibration software.


3. Application
 Calibrating Tesla meters and flux meters
To calibrate the Tesla meter:
  1. Output precision excitation current to the electromagnet through a precision DC excitation power supply.
  2. Place the precision magnetometer probe of TH8030 and the Tesla meter probe of the magnetometer to be calibrated in the same uniform area of the electromagnet.
  3. Compare the two indications to achieve calibration of the Tesla meter.
To calibrate the flux meter:
  1. Use the TH8030 built-in volt-second method fluxmeter calibrator to calibrate the fluxmeter of the magnetometer being calibrated.



 
 Measuring electromagnet magnetic field non-uniformity
  1. The excitation current is output to the electromagnet to be calibrated through the calibrated permanent magnet magnetic detector.
  2. Place the precision magnetometer probe of TH8030 at the center of the pole surface of the electromagnet to be calibrated.
  3. The host controls the intelligent positioning device of the probe to move the probe slowly to measure the non-uniformity of the magnetic field of the electromagnet.


 Measuring the coil constant
  1. The excitation current is output to the electromagnet through a precision DC excitation power supply.
  2. Place the precision magnetometer probe of TH8030 in the center of the pole surface of the electromagnet.
  3. Place the coil to be calibrated in the center of the electromagnet pole surface. After clearing the precision flux meter in the host computer, quickly pull out the coil, record the magnetic flux, and calculate the coil constant.


 
 Calibrating magnetic properties parameters
  1. Use the reference sample as the load, set the calibration point through the magnetometer to be calibrated, and output the excitation current.
  2. Use TH8030 and the magnetometer to be calibrated to simultaneously measure the remanence Br, coercivity Hc, intrinsic coercivity Hcj, and maximum magnetic energy product (BH)max of the reference sample to achieve calibration of the magnetic property parameters of permanent magnet materials.



4. Specifications (Host)
4.1 Precision volt-second magnetic flux calibrator
Voltage outputRange2 mV,20 mV,200 mV,2V
Uncertainty(k=2)0.01%*RD+0.005%*RG or
0.01%*RD + 0.2 μV; use the larger value of the two
Adjust fineness0.005%*RG
Protective functionShort circuit protection, overload protection
Adjustable timerPulse width range0.1 s~5 s
Uncertainty (k=2)0.005%*RG
Flux outputFluxCombination of voltage and time
Range0.1 mWb~10 Wb
Display digits7-digit decimal display
Uncertainty(k=2)200 ppm*RD + 0.1μWb

4.2 Precision flux meter
Magnetic flux measurement range0.2 mWb~10 Wb
Minimum resolution10 nWb
Magnetic flux measurement uncertainty (k=2)0.05%*RD + 5 μWb
Zero drift typical value0.5 μWb/min
Display digits6-digit display

4.3 Precision magnetometer
Measurement rangeResolutionMeasurement uncertainty (k=2) A%*RD+BTemperature coefficient
± ppm/ºC
Zero drift
± μT/h
3 mT1 nT0.1% + 100 μT5015
30 mT10 nT0.05% + 100 μT5020
300 mT100 nT0.05% + 100 μT5050
2500 mT1 μT0.05% + 150 μT5075


4.4 Environmental parameter measurement
Temperature and humidity measurementProbeTemperature and humidity probe
Environmental magnetic field measurementRange1 mT
Display digits5-digit display
ProbeThree-dimensional magnetic field sensing probe
Measurement uncertainty (k=2)0.5%

4.5 General specification
Power supplyAC ( 220 ± 22 ) V,( 50 ± 2 ) Hz
Temperature performance Working temperature:0°C~50°C; Storage temperature:-20°C~70°C
Humidity performanceWorking humidity: 40%~80% R·H; non-condensing
Storage humidity: < 80% R·H, non-condensing

5. Specification (Precision DC excitation power supply)
Maximum output current± 25 A
Measurement uncertainty (k=2)0.005%*RG
Protective functionOpen circuit protection, overload protection
Power supplyAC ( 220 ± 22 ) V,( 50 ± 2 ) Hz
 