Main Applications
Main Features
CN1 [DI] | |||
No. | Pin | Signal Name | Description |
1 | COM | COM | DI Common Terminal [DC-]. |
2 | DI1 | AUTO | Auto/Manual. ON: Auto state. OFF: Manual state / Emergency Stop. |
3 | DI2 | START | Start / Clear Alarm. In running process: Clear Alarm. Pause state: Clear Alarm & Recover Running. OFF→ON→OFF. |
4 | DI3 | PAUSE | Manual Pause. OFF→ON→OFF. |
5 | DI4 | DUMP_I | Manual Dump. 1. Stop state: ON: Manual Dump; OFF: Stop. 2. In the Auto-batching process If [312] 'Dumping Mode' = '0. HAnd', it's necessary to input the DI signal 'Manual 'Dump' (OFF→ON→OFF) for triggering the dumping process. |
6 | DI5 | STOP | Normal Stop [Last Batch]. OFF→ON→OFF: The batching process will stop automatically after the present batch finished. |
7 | DI6 | SP3_I | Manual Dribble Re-feed. Valid at Pause state with Mn's Low Tolerance Alarm. ON: Start Mn's Dribble Feed. OFF: Stop Mn's Dribble Feed. |