Technical parameters | GRT8-ST |
Function | Delay ON star /Delta |
Supply terminals | A1-A2 |
Voltage range | AC/DC 12-240V(50-60Hz) |
Burden | AC 0.3-2VA/DC 0.1-1.2W |
Voltage range | AC 230V(50-60Hz) |
Power input | AC max.6VA/1.3W |
Supply voltage tolerance | -15%;+10% |
Supply indication | green LED |
Time ranges | Range of time delay t1:0.1s-10min,Switch time t2:0.1s-10s |
Time setting | potentiometer |
Time deviation | 10%-mechanical setting |
Repeat accuracy | 0.2%-set value stability |
Temperature coefficient | 0.05%/ºC,at=20ºC(0.05%ºF,at=68ºF) |
Output | 2×SPDT |
Current rating | 16A(AC1) |
Switching voltage | 250VAC/24VDC |
Min.breaking capacity DC | 500mW |
Output indication | red LED |
Mechanical life | 1×107 |
Electrical life(AC1) | 1×105 |
Reset time | max.200ms |
Operating temperature | -20ºC to+55ºC(-4ºFto131ºF) |
Storage temperature | -35ºC to+75ºC(-22ºFto158ºF) |
Mounting/DIN rail | Din rail EN/IEC 60715 |
Protection degree | IP40 for front panel/IP20 terminals |
Operating position | any |
Overvoltage category | III. |
Pollution degree | 2 |
Max.cable size(mm 2) | solid wire max.1×2.5or 2×1.5/with sleeve max.1×2.5(AWG 12) |
Tightening torque | 0.4Nm |
Dimensions | 90×18×64mm |
Weight | W240-82g,A230-80g |
Standards | EN 61812-1,IEC6947-5-1 |