LUGB flange clamped vortex street steam flowmeter is a commonly used structure, its body itself does not have a connection flange, in connection with the pipe, the flowmeter clamped between two special flanges, and then bolted. It is characterized by small size and simple and compact structure. At the same time, special flanges and fastening bolts are provided, so the installation cost is low and the installation is very convenient.
Vortex flowmeter is a new flowmeter developed on the basis of Karman vortex principle. Because it has the advantages that other flowmeters can not be combined, since the 1970s has been rapid development, according to the data in the close, now Japan, Europe and the United States and other developed countries use the proportion of vortex flowmeter has risen significantly, has been widely used in various fields. It will occupy a leading position in the future flow meters and is an ideal alternative to orifice flowmeters. Vortex flowmeters are suitable for measuring the mass flow and volume flow of superheated steam, saturated steam, compressed air, general gas, water and liquid.
The company produced LUGB vortex flowmeter, there are remote transmission type, field display type, temperature and pressure automatic compensation type. Can be widely used in chemical, petroleum, metallurgy, light industry, environmental protection, municipal, electric power and other departments.
Performance | Technical parameter | ||
Measuring medium | Steam, compressed air, liquid (single phase media) | ||
Medium temperature | -40ºC~+350ºC | ||
Medium pressure | 1.6,2.5,4.0Mpa | ||
Range ratio | 1:8~1-30(air at reference scale) 1:8~1:40(Refer to normal temperature water) | ||
Measuring range | Liquid 0.4 ~ 0.7m/s Gas 4.0 ~ 60m/s Steam 5.0 ~ 70m/s | ||
Specification | DN25~DN300mm | ||
Material | 304, 316L a variety of materials | ||
Reynolds number | Normal 2 x 104Cd to 7 x 106 | ||
Drag coefficient | Cd≤2.6 | ||
Vibration acceleration | LUGB type≤0.2g | ||
Class of protection | IP65 | ||
Explosion-proof class | (ia) II CT6 | ||
Accuracy | Level 1.0, level 1.5 | ||
Environmental condition | Ambient temperature | -40ºC~+55ºC(non-explosion-proof place) -20ºC~+55ºC(explosion-proof place) | |
Relative humidity | ≤85% | ||
Atmospheric pressure | 86~106Kpa | ||
Power supply | Non-explosion-proof type | Pulse type | +12VDC 20mA |
current type | +24VDC 20mA | ||
Output signal | Frequency pulse signal 2 ~ 3000Hz Low level ≤1V High level ≥6V | ||
Two-wire 4-20mA signal (isolated output) load ≤500Ω |