Digital Mammography Machine Foinoe Portable X-ray Digital Medical X-ray Machine Digital Mammography Model Medical X-ray Equipments & Accessories

Min.Order: 1
Product origin: Nanjing, Jiangsu, China
Infringement complaint: complaintComplaint
US$ 25500 ~ 78000

Description
Product Description

Digital Mammography Medical X-ray Radiographic System DM-160MA-1

Specifications

Configuration 

No.BrandModelProduct NameQuantity
1FoinoeTSM-1DX Ray Diagnostic Workstation1
2Kang ZhongCareView 750MX-ray Imaging System1
3FoinoeFSQ-M-VMX1High Frequency Generator1
4FoinoeQG-M1X-Ray Tube1
5FoinoeXSM-2Collimator1
6FoinoeDM156-1C-Arm Stand1
7FoinoeYPQM-1/YPQM-2Compression Device2
8FoinoeYPQM-3Compression Device (Optional)1
9LinakFSE1200022/FSR0W00000/FSL0W00000Foot Switch (A set of two)1
10SteuteMKF41PW-MEDGP47Foot Switch (Optional)1
11JPIJPI 2100Grid (Optional)1
12Foinoe/High Voltage Cables2
13 /Emergency Brake Switch1
14 /Patient Handle1
15 /Display2
16 /Computer2
17 /Report Laser Printer1

SYSTEM FEATURES
  1. User friendly design with auto-release breast compressor, it could release after each exposure, which will offer a comfortable experience for patients.
  2. 77μm detector could supply high quality image output with 4096x3072 resolution, and 24x30cm large view size, enable to assist best diagnosis even small nidus.
  3. One key positioning function and isocentric arm system can help radiographer make common position efficiently and safely.
  4. Mammography CAA Software, with GPU (Graphics Processing Unit) High Speed Image Processing Module, EAE high efficiency automatically intensifying Module, decrease image processing time, binging better image quality, help to find tiny lesions.
  5. Indicator to show the pressure, angle and thickness of breast, makes the examination visually and measurable.
AEC function enable to optimize the good image quality and dose management.

Digital Mammography FPD (CareView 750M)
  1. Application: General radiography
  2. Scintillator: CsI
  3. Pixel Size: 77μm
  4. Pixel matrix: 4096 x 3072
  5. Field of view: 24 x 30cm (10x12inch)
  6. Gradation: 16bits
  7. Resolution: 6lp/mm
  8. Communication: Gigabit-Ethernet
  9. Weight: 2.3kg
  10. Dimension: 33.3 x 26.8 x 1.5 cm
  11. AEC function available
DXRay Diagnostic Workstation (TSM-1)
Diagnostic workstation
  1. CPU: Inter Core i5
  2. OS: Windows 7 64bit
  3. Image Capture Memory: 8GB,Hard Drive: 500GBd
  4. Medical Monitor: 2M
  5. CD/DVD recording/burning
DXRayDiagnost software
Case management
  1. Case management function: including the management of patient information, exam information and images.
  2. Worklist enquiry service following standard DICOM3.0 may inquiry from HIS/PACS and download case information. 

Image acquisition

  1. Acquisition system: positive and negative film image capture can be configured;
  2. Real time automatic window width level adjustment;
  3. Real time ROI (region of interests) clipping;
  4. Real time enhancement;
  5. Selecting image and rotation according to different body postures;
  6. Displaying patient information, examination information, device information and image information

Image processing

  1. Adjustment of window width, window level, Gamma, and LUT curve.
  2. Positive and negative film switchover, image zoom, translation, mirror image, rotation, magnified display;
  3. Image enhancement, noise reduction: Scheme and level of image enhancement and noise reduction can be adjusted according to different body postures.
  4. Image labeling function: including drawing straight line, rectangle, polygon, arrow and text;
  5. Real time reminding the free space of image disk of the system.
  6. RT prompt system can be used for store size of the disk space of image.

Image output

  1. Sending SCU with DICOM: support sending image to any PACS and workstations following Standard DICOM3.0;
Receiving SCP server with DICOM: support receiving image following Standard DICOM3.0 from any workstation.

5KW High Frequency Generator (FSQ-M-VMX1)
  1. Nominal supply voltage(50/60Hz): Single-phase 180-260VAC
  2. Power: 5 KW(31KV and 160mA)
  3. Output Voltage: 20-40KV
  4. Input Voltage: 220V
  5. Range of mAs: 10 - 120mAs /10-500mAs
  6. Range of mA: 10-200mA
Range of ms: 5ms-10000ms

X-Ray tube (QG-M1)
  1. Target Material: Molybdenum
  2. Focus: 0.1/0.3mm
  3. Angle of target: 15°
Anode Heat Capacity: 300kHU

Compression System and C Arm System (DM156-1)
  1. Compressor: Automatic Release Function and Manual Control Function\
  2. Size of compressor: 240x310mm, 100x100mm, 200x280mm
  3. Range of compressor: 280mm
  4. Pressure: 0-196N, shows on the indicator
  5. Distance from focus to the ground: 1420mm-2020mm,
  6. Arm Rotating Angle: -135°-+180°, shows on the indicator
  7. SID: 650mm
  8. Equipped with two rotating, lifting control switch
  9. Thickness detection, shows on the indicator
  10. One key positioning: +50°, 0°, -50°
  11. Dimension: 1900x1000x1135mm
  12. Grid: JPI 2100
  13. Ratio: 4:1
  14. Focus: 645mm
Line pairs: 332.5line/inch
Detailed Photos

 






 

Clinical Image

Other Model

Company Profile

 

Customer Photo

 

Good Comments from Our Clients



Send your message to us and click "Send" now 
Product Tag:
Related categories:
Scroll to Top