Design code | Rated Voltage (KV) | Rated mechanical stretch load (kn) | Structure Height (mm) | Minimum arcing distance (mm) | Minimum nominal creepage distance (mm) | Diameter of shed D(mm) | Lightning impulse withstand voltage [peak]≥(KV)) | Power frequency withstand voltage (wet)≥(KV) |
FPQ-10/4T20 | 10 | 4 | 215 | 125 | 280 | 148/118 | 75 | 42 |
FPQ4-10/5T20 | 10 | 5 | 250 | 165 | 460 | 148/118 | 105 | 42 |
FPS-105/5 | 10 | 5 | 250 | 180 | 380 | 90 | 105 | 42 |
Design code | Rated Voltage (KV) | Rated mechanical stretch load (kn) | Structure Height (mm) | Minimum arcing distance (mm) | Minimum nominal creepage distance (mm) | Lightning impulse withstand voltage [peak]≥(KV)) | Power frequency withstand voltage (wet)≥(KV) | Structure of connected marks |
FXBW4-10/70 | 10 | 70 | 400 | 200 | 480 | 75 | 42 | 16 |
FXBW4-10/100 | 10 | 100 | 450 | 200 | 480 | 75 | 42 | 16 |
FXBW4-35/70 | 35 | 70 | 650 | 450 | 1320 | 230 | 95 | 16 |
FXBW4-35/100 | 35 | 100 | 720 | 520 | 1600 | 230 | 95 | 16 |
FXBW4-6670 | 66 | 70 | 900 | 710 | 2140 | 410 | 185 | 16 |
FXBW4-66/100 | 66 | 100 | 940 | 710 | 2140 | 410 | 185 | 16 |
FXBW4-110/100 | 110 | 100 | 1240 | 1000 | 3315 | 550 | 230 | 16 |
FXBW4-145/120 | 145 | 120 | 1480 | 1240 | 4123 | 725 | 355 | 16 |
FXBW4-220/100 | 220 | 100 | 2240 | 1900 | 6300 | 1000 | 935 | 16 |
FXBW4-220/160 | 220 | 160 | 2240 | 1900 | 6300 | 1000 | 935 | 16 |
FXBW4-330/160 | 330 | 160 | 2990 | 2600 | 9075 | 1425 | 570 | 16 |
FXBW-12/70 | 12 | 70 | 390 | 180 | 460 | 105 | 42 | 16 |
FXBW-15/70 | 15 | 70 | 445 | 225 | 620 | 105 | 42 | 16 |
FXBW-24/70 | 24 | 70 | 450 | 235 | 635 | 150 | 65 | 16 |
FXBW-24/70 | 24 | 70 | 450 | 265 | 643 | 150 | 65 | 16 |
FXBW-28/70 | 28 | 70 | 560 | 380 | 1250 | 230 | 95 | 16 |
FXBW-33/70 | 33 | 70 | 560 | 380 | 1130 | 230 | 95 | 16 |
FXBW-35/70 | 35 | 70 | 550 | 390 | 850 | 230 | 95 | 16 |
FXBW-36/70 | 36 | 70 | 580 | 380 | 1250 | 230 | 95 | 16 |
FPQ2-24/4 | 24 | 4 | 310 | 180 | 645 | 150 | 65 | 16 |
FPQ2-36/5 | 36 | 5 | 620 | 460 | 1160 | 230 | 95 | 16 |
Design code | Rated Voltage (KV) | Rated mechanical stretch load (kn) | Structure Height (mm) | Minimum arcing distance (mm) | Minimum nominal creepage distance (mm) | Diameter of shed D(mm) | Lightning impulse withstand voltage [peak]≥(KV)) | Power frequency withstand voltage (wet)≥(KV) |
FZSW-10/4 | 10 | 4 | 215 | 125 | 290 | 100/90 | 75 | 42 |
FZSW-20/8 | 20 | 8 | 400 | 320 | 750 | 142 | 150 | 65 |
FZSW-35/6 | 35 | 6 | 450 | 360 | 946 | 148/118 | 185 | 95 |
FZSW-66/6 | 66 | 6 | 760 | 630 | 1886 | 160/130 | 410 | 185 |
FZSW-66/8 | 66 | 8 | 760 | 630 | 2010 | 220/190 | 410 | 185 |
FZSW- 110/10 | 110 | 10 | 1220 | 1080 | 3530 | 220/190 | 500 | 230 |
FZSW-220/10 | 220 | 10 | 2440 | 2200 | 7060 | 220/190 | 1000 | 395 |
Design code | Rated Voltage (KV) | Rated mechanical stretch load (kn) | Structure Height (mm) | Minimum nominal creepage distance (mm) | Lightning impulse withstand voltage [peak]≥(KV)) | Power frequency withstand voltage (wet)≥(KV) | Structure of connected marks |
FQX1-25 | 25 | 60 | 650 | 1400 | 270 | 130 | aa |
FQX2-25 | 25 | 20 | 840 | 1400 | 270 | 130 | bb |
FQX3-25* | 25 | 20 | 930 | 1400 | 270 | 130 | bb |
FQX3-25* | 25 | 20 | 760 | 1400 | 270 | 130 | ac |
FQX4-25 | 25 | 20 | 806 | 1400 | 270 | 130 | gh |
FQX5-25 | 25 | 60 | 645 | 1400 | 270 | 130 | af |
FQE3-25* | 25 | 60 | 640 | 1400 | 270 | 130 | ff |
FQE4-25* | 25 | 20 | 836 | 1400 | 270 | 130 | gc |
FQE5-25* | 25 | 20 | 695 | 1400 | 270 | 130 | de |
FQE5-25 | 25 | 20 | 695 | 1400 | 270 | 130 | gi |
Design code | Central distance between channel and installation hole | Min. Electric arc distance (mm) | Min nominal creepage distance (mm) | Installation hole diameter (mm) | Rated bent withstand load (KN) | 1 min power frequency wet withstand voltage(KN) | Full wave lightning impulse withstand woltage(peak value) (KV) |
FSW3-10/2.5 | 390 | 274 | 362 | 18 | 2.5 | 45 | 165 |
FSW3-10/5 | 400 | 280 | 410 | 18 | 5.0 | 50 | 185 |
FSW3-35/5 | 620 | 490 | 1060 | 22 | 5.0 | 100 | 265 |
FSW3-66/10 | 890 | 735 | 1815 | 23 | 6.0 | 185 | 410 |
FSW3-100/10 | 1240 | 1070 | 3180 | 24 | 10 | 230 | 550 |