X-ray Generator | |
Ray Beam direction | Bottom-illuminated |
Tube current | 0.4~0.5mA(adjustable) |
Tube voltage | 100-160 kV(adjustable) |
Ray beam divergence angle | 60° |
The cooling / work cycle | Sealed oil cooling / 100% |
Image Processing System | |
X-ray sensor | L-shaped photodiode array detector (C), 24bit depth |
Monitor | One 21.5-inch LCD monitor, 1920*1080 |
Color image display | 24-bit true color display |
Edge Enhancement | the outline of objects will be more clear |
Super Image Enhancement | the details of the image are more clear |
High penetration display | improve image contrast in bright areas, so the easy penetrating area will be more clear |
Low penetration display | improve image contrast in dark areas, so the difficult penetrating area will be more clear |
Magnifier | local amplification function |
Brighten / darken | Increase/ decrease image brightness |
Image pull back / front pull | Show the top 20 images, and the current image can be any image processing |
Image Restoration | Restored to its original state |
Image Storage | Real-time save any image, any image can be processed arbitrarily ,continuous work to save |
Environmental conditions | |
Operating temperature / humidity | 0ºC~45ºC/20%~95% (No condensation) |
Storage temperature / humidity | -20ºC~60ºC/20%~95% (No condensation) |
Operating Voltage | 90V~250V 50/60Hz |
Power consumption | 1.0KW(maximum) |
Noise level | <60dB (A) |
Technical Standards | Technical Parameters |
Tunnel size | 500(W)×300(H)mm |
Conveyor speed | 0.22m/s |
Load | 150 kg |
Resolution | ∮0.0787 mm |
Penetration | ≥40 mm steel plate |
Monitor | One 21.5-inch LCD monitor, 1920*1080, no console desk |
Storage | 500G hard drive to save any image in real time, can store more than 100,000 and can make any image processing, and continuous work to save. |
Noise | < 60dB(A) |
Operating system | Embedded Linux operating system, multi core ARM, stable and reliable |
Film Safety | Safety to the ISO1600 |
Leaking radiation dose rate | Away from any device outer surface of 5cm, the ray irradiation leak rate should be < 0.05µGy/H |
Dimensions | 1660(L)*746(W)*1165(H) |
NW / GW | 260 kg / 350 kg |