Landworld Bidirectional Power Supply 11kw Obc+3kw DC/DC DC+Obc

Min.Order: 1
Product origin: Shenzhen, Guangdong, China
Infringement complaint: complaintComplaint
US$ 1951

Description

Product Features:
  1. Body Size::372x240x98mm
  2. Weight::≤14KG
  3. Cooling method:liquid cooled,flow≥10L/min
  4. Ip rating:IP67
  5. Support inverter function
  6. Support on-line upgrading and fault diagnosis
  7. Full digital software design, Redundant protection function design

Main Technical Parameters
 
ItemsTechnical SpecificationRemarks
OBC Electrical Features
Nominal output power11KW 
Input Voltage304-456VAC(three phase four wire)Sigle-phase176-264VAC
Input current32A Max 
Power factor≥0.99(220Vac,full load) 
Output voltage range250-450VDCCan be adjusted according to battery voltage
Max output current32A 
Efficiency≥94%Nominal voltage
Voltage accuracy±1% 
Current accuracy±1% 
Input voltage range
Output voltage250-450VDC 
Power220VAC(±5%)(single-phase) 
Efficiency6kVA(single-phase) 
Output harmonics(THDv)≥94% 
Dynamic response<3%(linear load) 
Leakage current protection threshold60ms(linear load) 
Input voltage range≤30mA 
DCDC features
Input voltage250-450VDC 
Output current <16A @240Vdc full load 
Efficiency≥94% 
Output voltage9-16V 
Nominal voltage13.8V 
Nominal output current218A 
Nominal power3KW 
Peak power3.6KW 
Voltage ripple300mV Max 
Inverter features
Operating temp.-40-85ºCCoolant inlet temperature
Low voltage wake-up12Vdc&200mAmax(WAKE_UPsignal)Wake up BMS/VCU
Wake-up modeCAN,AC,CC/CP,ENSupport reserve charging
CAN communicationCAN-BUS 
Static current≤1mASleep mode/ consume battery current at stop status
ProtectionInput OVP, UVP, output OVP, UVP, OTP, OCP, output short circuit protection, communication fault protection 
EMCGB/T18387-2008,EN 55022  