MPPT/PWM Charging Function 1kw 2kw 3kw 5kw Wind Solar Hybrid Controller with Dump Load

Min.Order: 1
Product origin: Yangzhou, Jiangsu, China
Infringement complaint: complaintComplaint
US$ 330 ~ 500

Description
Detail Images
Model Specification
Product NameRated Input PowerRated Battery VoltageOptional FunctionFeature
WWSWind solar hybrid controller0.6KW24VNormalNormal
1KW48VLow Voltage ChargeRS232
2KW96VBuck Voltage ChargeRS485
3KW120VEconomicSolar Dumpload Separately
5KW192VMicro-current Charge
Wind Turbine
Single Phase DC
10KW220V
RS232
Wind Turbine
Single Phase DC,
RS232
20KW240V
RS485
Wind Turbine
Single Phase DC,
RS232
Parameters
ParametersWWS20-48
Rated Battery Voltage48V
Rated Wind Turbine Input Power2KW
Maximum Wind Turbine Input Power3KW
Wind turbine brake current42A
Rated solar Input Power600W
Charge Shutoff Voltage58V
Stand by power loss≤65mA
Display modeLCD
Cool modeFan
Protections 
Reverse battery protectionAnti-reverse-connection protection device in the inside of controller.
Open circuit protectionThe controller will not be demaged if the battary in open circuit.
Solar anti-charge protectionBattery don't charge PV board in reverse.
Solar anti-reverse protectionThe controller will not be damaged when the PV is reverse-connection.
Manual brakeWind generator stop turning or slowing turning.
Lightning protectionLightning protection in inside of the controller.
Protection gradeIP(Indoor)
Insulation resistanceResistance between DC/AC input and the housing>=50ΜΩ.
System parameters 
Ambient Temperature & Humidity Range-20~+55ºC/35~85%RH(No Condensation)
Altitude≤4000m
Dimensions (L*W*H)445*425*170mm
Net Weight11kg
Troubleshooting
Trouble TapyAnalysis TroubleExclude and resolve
LCD no dispalyDC circuit breaker not close between battery and controller.Closing the breaker
The connecting line is insecure between battery and controllerVisual connection,reconnect and Tighten it.
The volage of battery is too lowCheck whether the controller paremeter to match the paremeter system or not.
Battery banks have borken,replace them.
The connecting line is reverse-connection in positive and negative pole between battery and controller.Replace the fuse of the inner of controller and correct connnect the battery banks.
Not chargeThe connecting line of PV mudule and controller is fall off or loose.Reconnect and tighten the connecting line of system
The connecting line is reverse-connection in positive and negative pole between the PV board and controller.To be corrected reconnect between PV board and controller.

Company Profile