MODEL | 60KW | 120KW | 180KW |
INPUT |
Nominal Input Voltage | 380 VAC ± 15% |
Acceptable Input Voltage Range | 3-phase, 3ph + N + PE |
Working Voltage Range | 50 - 60 Hz |
Maximum Input Current | 100A | 260A | 300A |
Frequency Range | <= 5% |
Input Power Factor | > 0.99 @nominal voltage (100% load) |
OUTPUT |
Output Current Range (based on 2-output) | 2 ~ 200A | 2 ~ 250 A | 2 ~ 250 A |
Output Voltage Range | 200~750VDC (600~750VDC in constant power mode) |
Power Module | 30kW x 2 pcs | 30kW x 4 pcs | 30kW x6 pcs |
Efficiency | > 94% |
Module Output Current Unbalancce | < 5% |
Module Output Voltage Ripple | < 0.5 |
Module Output Voltage Precision | < 0.5% |
MModule Output Current Precision | < 1% |
Connector Single Mode (max.) | CCS2 (60kW) ChAdeMO (50kW) | CCS2 (120kW) | CCS2 (180kW) ChAdeMO (50kW) |
ChAdeMO (50kW) |
Connector Double Mode (max.) | CCS2 (30kW) ChAdeMO (50kW) | CCS2 (60kW) | CCS2 (90kW) |
ChAdeMO (50kW) | ChAdeMO (50kW) |
Power Distribution | Single plug mode / Average output mode |
PROTECTION |
Charger Safety Protection | Over/Under voltage, overload, output power limit function, short circuit, anti-access, earth leakage, lightning and overheat |
protection |
Interface Safety Portection | Circuit discharge function, insulation monitoring device (IMD) and battery reverse parity protection |
USER INTERFACE |
Status Indiators | Power on, charging and fault |
Communication Protocol | OCPP 1.6 |
Connection Communication Mode | In accordance with DIN 70121 and ISO 15118 standard |
Connection Standard | CCS2 (IEC61851-23) and CHAdeMO 1.0 |
ENVIRONMENT |
Operating Temperature | -25°C to 50°C |
Humidity | 0 - 95% (non-condensing) |
Altitude | < 2000m |
Noise Level | <65dB |
PHYSICAL |
IP Protection | IP54 |
Cable Length | 5m |
Dimension, D x W x H (mm) | 750 x 530 x 1685, excluding plug and cable |
Net Weight (kgs) | 275 | 310 | 328 |