New Design 10 Years Connected Smoke Alarms Smoke Only Wireless Interconnected Smoke Alarm

Min.Order: 500
Product origin: Hangzhou, Zhejiang, China
Infringement complaint: complaintComplaint
US$ 9.5 ~ 12.5

Description
Built-in 3V lithium battery photoelectric smoke alarm with RF function
Technical Specifications:
Power Source DC 3V batteryLow Voltage Threshold ≤2.6V
Operation Current ≤8uAHush time 8minutes
Alarm Sensitivity 0.10 - 0.16dB/mProduct service life >10 years
Comply with standardEN 14604:2005/AC:2008Humidity Range < 93% relative humidity (RH)
Alarm Current ≤60mATemperature Range 0ºC to 40ºC
Alarm Volume >85dB(A) @ 3 meters.Size120mm in diameter x 35.5mm depth
Sound Pattern (BI 0.5s - pause 0.5s - BI 0.5s - pause 0.5s - BI 0.5s - pause 1.5s, with the RED LED flash, repeat this alarm pattern)
Details of the product function:
Standby mode After the product is installed, if the smoke alarm device is operating properly, the red LED flashes once every 48 seconds
Alarm mode When the smoke alarm device detects particles of combustion and the concentration of smoke reaches the alarm threshold, the red LED will flash once per second with pulsating alarm until the smoke is disappeared.
Low battery mode When the battery voltage is below threshold, the red LED will flash once every 48 seconds with a sound of "chirp"
Fault mode If the alarm detection signal decays below threshold, the alarm chirp occurs without LED flashes every 48 seconds.
Silence mode Press the test button at least 2 seconds, it will go into silence mode for approx 8 minutes. That will desensitize the alarm sensitivity temporarily. At this time, the red LED will flash once every 8 seconds;
Non disturb mode When the alarm device is in low battery mode, in order to avoid disturbing your at night, Please press the test button for 3 seconds which will mute this warning tone for about 14 hours. After 14 hours, the warning tone will still go off. The red LED will flash once every 48 seconds during No disturb mode.
Test mode Test the unit to ensure operate properly by pressing the test button. At this time, the red LED will flash once per second with pulsating alarm until test button is released.
Wireless interconnection alarm sound mode BI - BI - pause 1.2s, with the red LED flash, this alarm pattern is repeated.
NOTE WEEKLY TESTING ONE TIME IS REQUIRED.
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 