Conveyor Belt Counter Infrared Sensor 3m Automatic Induction Counter

Min.Order: 1
Product origin: Wenzhou, Zhejiang, China
Infringement complaint: complaintComplaint
US$ 68 ~ 72

Description

Conveyor belt counter Infrared sensor 3m Automatic Induction Counter

Product model:

Magnet induction 2cm,

U-shaped sensor,Metal objects 5MM,

Fiber Optic Sensor,Infrared sensor 30cm (single probe),

Infrared sensor 70cm (single probe),

Sensing 3m (double probe),

Laser on the number of 20m (double probe),

Laser on the number of 20m (double probe),Grating sensor,Plus control function.

Installation instructions:

          Single probe and the radio sensor to detect small objects when the distance is shortened (to 10 * 10CM objects as the standard)

         The distance between the single probe sensor and the black color object will be shortened.The detection distance of the object is shortened.

Precautions:

          The probe can not shake, the probe to keep clean, to avoid light exposure, object size, detection speed, objects can not overlap or Siamese.

Features of Counter:

       1. The user can modify the parameters, all the settings are not lost, even if the power is off. The range

of setting, please refer to the technical parameters.
       2. Count/Count meter, from small to large number, It has 1 second warning alarm when time is up. The switch of warning alarm can change by J8, "O" means "OPEN", "C" means "CLOSE".
 
       3. The working type of relay: when the counts reach the preset number , the relay pull up, and the relay
is released after reset.
       4. The instrument has the functions of viewing the cumulative number and resetting. " < " means view
the cumulative number, "∧" means reset button.
       5. Press 2 seconds " < ", the counter display the cumulative number. Release it and press it 2 seconds again, can reset the cumulative number. Press the "∧" or no operation, it can back to the count interface after 2 seconds.
      6. Power supply using polarity protection circuit, power reverse will not damage the instrument. DC 5V and DC7 ~ 30V can be switched by "J7" button.The default setting is DC7 ~ 30V.(Note: when J7 is switched to DC 5V, do not supply the DC7~30V voltage)
     7. Power off, the memory can be stored for 10 years.
     8. Wiring diagram
 
Note:
          IN+ and IN- is the input interface of trigger signal (When turn on the switch, trigger signal input
connect IN+,not IN-); VCC and GND is the input interface of instrument working voltage; S1+ and
S1- is the output interface of controlling relay normal open; S2+ and S2- is the output interface of
controlling relay normal close.
Technical Parameter of Counter:
Working Voltage/ CurrentDC5V or DC7~30V/300mA. DC5V and DC7~30V can be switched by J7 button.
Trigger signalSwitch signal; proximity/photoelectric/electric switch (PNP/NPN) Sine wave / square wave signal. Note: if speed is over 30, can not use the mechanical switch.
Count frequency+999~-999 time/s(adjustable),-1 means 1 second count 1 number,-2 means 2 second count 1 number…
Count range1~9999 time(×1, ×2, ×3..... ×999)
Meter length step selection range999×set length. Step length is the 1 pulse of counter
Magnification setting9999×999=9989001 time or mm/cm…,means the Maximum range is 99989001 time or mm/cm…
Alarm output delay time for turning on0.1~999.9s
Alarm output turn on time for delay0.1~999.8s or always turn on (999.9)
Set upPush the "SET" button for 3 second, and then to set up the parameter
Capacity of controlling relay outputAC250V/3A; DC30V/3A; Mechanical life ≥107
time, Electric life ≥105
Suffix combination of controlling relay outputCS5641D-1J; CS5641-1T
Suffix meaningC means: Without power off memory ; D means: Power off memory ;J means: relay output; T means level signal output
Connector typeL means: Vertical type; W means: Horizontal type
Display type4 digital, 0.56'' Bright red digital tube
Working temperature-10ºC~+60ºC; ≤85RH (No condensation)
Dimension79mm*43mm*25mm
Hole size76mm*39.5mm

 

 

Scroll to Top