Phase current output ( RMS ) | 0~40A/phase Output Precision 0.2 degree |
3-phase in parallel output (RMS) | 0~120A |
A Long-time Phase current | 10A |
Maximum output power of Phase current | 450VA |
Maximum output power of 3 parallel current | 900VA |
Maximum Permitted work time of 3 parallel current | 10s |
Frequency range | 0~1000Hz; |
Harmonic time | 2~20 |
Current output | 0~±10A / phase, 0~±30A / 3 parallel |
Output Precision | 0.5 degree |
Phase voltage output (RMS) | 0~120V/phase, accuracy: 0.5% |
Line voltage output (RMS) | 0~240V |
Phase voltage / Line voltage output power | 80VA/100VA |
Frequency range | 0~1000Hz accuracy: 0.001Hz |
Overtone order | 2~20 |
Phase voltage output range | 0~±160V accuracy: 0.5% |
Line voltage output range | 0~±320V |
Phase voltage / Line voltage output power | 70VA/140VA |
Switch input terminals | 8 pairs |
Dead contact | 1-20mA, 24V active output inside the device. |
Potential flip | 0--6V DC low level; 15-250V DC high level |
Switch output terminals | 4 pairs, dead contact, rupturing capacity: 110V/2A, 220V/1A |
Range | 0.1ms~9999s |
Accuracy | 0.1ms |
Dimension | 400×360×160mm³ |
Weight | 15Kg |