Type | - |
Current channel number | Standard six phase |
Voltage channel number | Standard six phase |
AC current output range | 30A / phase or 180A (six phase parallel) |
DC current output range | 10A DC /phase |
AC voltage output range | 120V AC /phase |
DC voltage output range | 160V DC / phase |
The virtual value of each phase output when six phase current output | 0~30A output precision 0.1 grade |
The virtual value of each phase output when three phase current output | 0~60A |
The virtual value of each phase output when three phase current output | 0~180A |
The allowed virtual value when the phase current work long time | 10A |
The maximum output power of phase current | 450VA |
The maximum output power when six phase parallel current output | 1000VA |
The allowed working time when six phase parallel current maximum output | 10S |
Frequency range | 0~1000Hz; |
Harmonic order | 2~20; |
Current output | 0~±10A / phase |
output precision | 0.2 grade |
The maximum load volatage output | 20V |
The virtual value of phase voltage output | 0~120V output precision 0.1 grade |
Line voltage range | 0~240V |
Phase voltage / Line voltage output power | 80VA/100VA |
Frequency range | 0~1000Hz |
Harmonic order | 2~20 |
The output amplitude of phase voltage | 0~±160V output precision 0.2 grade |
The output amplitude of line voltage | 0~±320V |
The output power of phase voltage/ line voltage | 70VA / 140VA |
8 channels input | |
Free contact | 1~20mA,24V |
Electric potential contacts | "0":0 ~ +6V; "1":+11 V ~ +250 V |
4 channels output | DC:220 V/0.2 A;AC:220 V/0.5 A |
Dimension | 455×530×220mm |
Weight | 32Kg |
0.1ms ~ 9999s | measurement accuracy <0.1ms |