10kv Resin Insulated Dry Type Transformer for Power Distribution Low Voltage Sc (B) Series Outside Switchgear Enclosure

Min.Order: 3
Product origin: Chongqing, China
Infringement complaint: complaintComplaint
US$ 50 ~ 500

Description
 
Product Description

    The epoxy resin insulated dry-type transformer provided by our company has the following characteristics:
Resistance to short circuit and strong weather resistance: foil coil is used at low pressure, segmenting cylinder coil is used at high pressure, the coil is poured in epoxy resin, and the coil adopts advanced directional gel technology, so that epoxy resin gel reaction is thorough without stress accumulation. Excellent mechanical strength and weather resistance.
    Strong overload capacity, good flame retardant: the use of international advanced saturated packing thin insulation epoxy resin vacuum casting technology, so that the product has greater heat dissipation capacity and good flame retardant performance.
High heat resistance grade: H grade epoxy resin is adopted, which has better heat resistance.
Small local discharge: vacuum pouring pressure infiltration process and uniform field strength design, avoid residual bubbles during pouring, local discharge is very small.
    Environmental adaptability: the packed epoxy resin material is closer to the thermal expansion coefficient of the coil conductor, the temperature or load fusion will not cause cracking of the resin, and the dense epoxy resin insulation layer has 100% moisture and water resistance.

Environmental conditions:
1.Environment: indoor
2.Altitude: below 1000m
3.Earthquake intensity: 8 degrees
4.Ambient temperature: -25ºC - +40ºC
5.pollution level: according to provisions of GB/T16434-1996 3 pollution level, the leakage distance not less than 2.5 cm/kV (highest working voltages).

Product Parameters
General technical parameters
projectunitTechnical parameters
The rated voltageKV10(20,35)/ 0.4
frequencyHz50 / 60
Tapping range ±2x2.5%
Insulation grade F
Local dischargePC<10
Insulation levelKV10KV  LI75AC35/AC3
20KV  LI125AC55/AC3
35KV  LI200AC85/AC3
Noise leveldBJB/T10888
Cooling way AN/AF
Protection grade IP20
Short circuit capacity GB1094.5
Mode of operation Operation mode


1.1 SC(B)10 series 10kV resin insulated dry type power transformer technical parameters
Product standardGB/T10228-2015  
GB1094.11-2007
GB/T1094.12-2013
Capacity
Sr
Short-circuit impedance
Uk%
No-load loss
Po
Load loss
Pw
No-load current
Io%
connetion symbolVoltage
kV
Tapping rangeNVHInsulation grade
kVA%(W)120ºC(W)%H.V.L.V.dB
3041907102Yyn0
OR
Dyn11
11
10.5
10
6.3
6
0.4±5%
±2×2.5%
63F
502701000263
8037013801.565
10040015701.565
12547018501.366
16054021301.366
20062025301.167
25072027601.167
3158803470169
4009803990169
50011604880170
630134058800.8571
6306130059600.8571
800152069600.8572
1000177081300.8572
1250209096900.8574
16002450117000.8575
20003050144000.777
25003600171000.778
160082450129000.8575
20003050159000.777
25003600188000.778

1.2 SC(B)11 series 10kV resin insulated dry type power transformer technical parameters
Product standardsGB/T10228-2015L.V. KV0.4
GB1094.11-2007
Insulation gradeFTapping range±5% OR ±2×2.5%
H.V. kV11,10.5,10,6.3,6connetion symbolYyn0 OR Dyn11
Capacity
Sr
Short-circuit impedance
Uk%
No-load loss
Po
Load loss
Pw
No-load current
Io%
Sound power level
NVH
Weight
G.W.
LBHlbhmkdg
kVA%W120ºC(W)%dBkgmmmmmmmmmmmmmmmmmmmm
3041707101.8633451250105012009356201013400275225280
5024010001.8634401250105012009556201041400300235290
8033013801.3655501300105012009706201059550320240295
10036015701.3656251350105012509906201087550325245300
12542018501.16678013501100125010106201102550335255310
16049021301.166100014001100130010306201118550345260315
2005602530167114014501100135010607101135660350265320
2506502760167136015001150140011007101159660365275325
31579034700.969158015001200145011507101194660375280330
40088039900.969185016001250160012608701284660400320360
500104048800.970216016001300165012908701355820410325365
6306117059600.7571227517001300165013408701340820445310350
800137069600.7572268019001300180015508701570820480330375
1000159081300.7572329018501300185015508701620820490330375
1250189096900.7574379019501300195015708701714820515365399
16002210117300.757548002000140021001650112017871070535380420
20002750144500.757756802150150022001770112018591070580405430
25003240171700.67867702200150022001870112019441070605425440
160082210129600.67548002000140021001650112017871070535380420
20002750159600.757756802150150022001770112018591070580405430
25003240188900.67867702200150022001870112019441070605425440

1.3 Technical parameters of 10kV class resin insulated dry type on-load voltage regulating power transformer
Product standardGB/T10228-2015  
GB1094.11-2007
GB/T1094.12-2013
Capacity
Sr
Short-circuit impedance
Uk%
No-load loss
Po
Load loss
Pw
No-load current
Io%
connetion symbolVoltage
kV
Tapping rangeNVHInsulation grade
kVA%(W)120ºC(W)%H.V.L.V.dB
315499036101.1Yyn0 Dyn1111
10.5
10
6.3
6
0.4±3×2.5%±4×2.5%69F
400112542751.169
500129652251.170
63014946175171
630614406365171
80017107505172
1000198087880.8572
12502340104500.8574
16002727124450.8575
20003420152000.777
25003960181450.778

1.4 Technical parameters of 20kV class resin insulated dry type on-load voltage regulating power transformer
Product standardGB/T10228-2015  
GB1094.11-2007
GB/T1094.12-2013
Capacity
Sr
Short-circuit impedance
Uk%
No-load loss
Po
Load loss
Pw
No-load current
Io%
connetion symbolVoltage
kV
Tapping rangeNVHInsulation grade
kVA%(W)120ºC(W)%H.V.L.V.dB
50634012302Yyn0 Dyn1120
22
24
0.4±5%
±2×2.5%
64F
10054019901.865
16067024701.566
20073029401.568
25084034201.368
31597040801.370
400115048401.170
500135057901.170
63015306840172
80017508260172
1000207097800.8572
12502380115000.8576
16002790138000.8576
20003240163000.878
25003870193000.878
200083240178000.878
25003870212000.878

1.5 Technical parameters of 35kV class 10 resin insulated dry type power transformer
Capacity
Sr
Short-circuit impedance
Uk%
No-load loss
Po
Load loss
Pw
No-load current
Io%
connetion symbolVoltage
kV
Tapping rangeNVHInsulation grade
kVA%(W)120ºC(W)%H.V.L.V.dB
50645014202.3Yyn0 Dyn1133
35
36.5
38.5
0.4±5%
±2×2.5%
64F
8055018202.364
1006302090265
16079028101.566
20088033201.568
25099038001.368
315117045101.370
400137054101.170
500162066501.170
63018607690172
80021609120172
10002430104000.7572
12502830127000.7576
16003240154000.7576
20003820182000.7578
25004450218000.7578
8006225094000.95Yyn0 Dyn11
Yd11
3.15
6
6.3
10
10.5
11
72
10002670109000.9572
12503130129000.8576
16003690154000.8576
200074230182000.7578
25004860218000.7578
315086030245000.778
40007020294000.785
50008370349000.685
63009900408000.685
8000911300460000.5Dyn11
YNd11
Yd11
88
1000012900555000.588
1250015700646000.46
6.3
10
10.5
11
88
1600019300760000.493
200001022900855000.3593
25000271001010000.3593

1.6 SC(B)H15 series 10kV class resin insulated amorphous alloy dry distribution transformer technical parameters table
 
Product standardsGB/T10228-2015,GB/T22072-2018,GB/T1094.12-2013L.V. KV0.4
Insulation gradeFTapping range±5% OR ±2×2.5%
H.V. kV11,10.5,10,6.3,6connetion symbolYyn0 OR Dyn11
Capacity
Sr
Short-circuit impedance
Uk%
No-load loss
Po
Load loss
Pw
No-load current
Io%
Sound power level
NVH
Weight
G.W.
lbhmkdg
kVA%W120ºC(W)%dBkgmmmmmmmmmmmmmm
304707100.6603459356201013400275225280
509010000.5604409556201041400300235290
8012013800.5625509706201059550320240295
10013015700.5626259906201087550325245300
12515018500.46378010106201102550335255310
16017021300.463100010306201118550345260315
20020025300.464114010607101135660350265320
25023027600.464136011007101159660365275325
31528034700.366158011507101194660375280330
40031039900.366185012608701284660400320360
50036048800.367216012908701355820410325365
63042058800.368226513408701340820445310350
630641059600.368227513408701340820445310350
80048069600.369268015508701570820480330375
100055081300.269329015508701620820490330375
125065096900.271379015708701714820515365399
1600760117300.27248001650112017871070535380420
20001000144500.27456801770112018591070580405430
25001200171700.27567701870112019441070605425440
16008760129600.27249501730112018801070560400440
20001000159600.27458501860112019501070610430450
25001200188900.27569731960112020401070640450460
Certifications

 

Company Profile

  Chongqing Lianwei Power Technology development Co., Ltd.(Tongxun Power Industry Co., Ltd.)  was established in April 1989, located in Lidu Industrial Park, Fuling District, Chongqing. It has a 30-year history of production and development of complete electrical equipment. The company's predecessor is Fuling Three Gorges Electric Appliance Factory of Chongqing Yuneng Group, which was later assigned to Chongqing East Asia Group. In 2006, it was transformed into Chongqing Dixun Electric Technology Co., Ltd. and in 2013, it was renamed Chongqing Taiwei Electric Equipment Co., Ltd. in October 2015, it was reorganized into Chongqing Lianwei Power Technology development Co., Ltd.(Tongxun Power Industry Co., Ltd.)with wholly-owned subsidiaries of Lanzhou Changyao Distribution Engineering Co., Ltd., Lanzhou Guowei Power Supply Co., Ltd. and Chongqing Lianwei Power Technology Development Co., Ltd. The company is a group with integrated the general contracting of electric power projects, the loading, repairing, testing, manufacturing of electric power equipment, operation and maintenance of electric power systems and import and export trade.

     Since 1989, being in line with the "Honesty and Trustworthy, customer first" corporate purpose and adherence to the "innovative, pragmatic, pioneering and enterprising" spirit, the company has shaped the "integrity, excellence, exquisite, value" brand image. Since 2000, the company has been successively awarded the following honorary titles: "Quality Designated Demonstration Unit", "Chongqing Famous Product", "Best District Civilization Unit", "A Class Taxpayer", and "National Quality Stable Qualified Product". The company has one patent for invention and six patents for utility model.

    Chongqing Lianwei Power Technology development Co., Ltd.(Tongxun Power Industry Co., Ltd.)  is looking forward to working with you to create a bright and brilliant tomorrow with good corporate reputation, excellent .

Our Advantages

 

Engineering cases
Tajikistan dangora 220KV substation
Katabang thermal power plant, Indonesia
Coal-fired power plant in riau, Indonesia
Vietnam north electric co. 's Hanoi van doon substation
East timor substation for Chinese nuclear industry
China institute of engineering physics
Xi 'an, China aviation industry corporation
Panzhihua xingang vanadium titanium xichang production
base
Longdong hydropower station in ya 'an, sichuan province
Batang langda hydropower station in ganzi prefecture
Sichuan guangan forward substation
Xiaojin county jiesigou secondary hydropower station
Luzhou hejiang longtan substation
Yunnan diqing north substation
Country garden lanzhou new city project
Country garden lanzhou new district project
Deyang country garden, sichuan
Nanchong country garden, sichuan
Guiyang poly group
Chongqing poly group
China railway group fuling beishan new town project
Raffles plaza, chongqing
Chongqing jiangbei international airport
Datang international wulong xingshun wind farm
Xiuzhou photovoltaic power generation project in jiaxing
Jiangsu dongtai photovoltaic power project
Guizhou kaiphosphorus holding group co. LTD
Chongqing jianfeng group
Chongqing huafeng group
Chongqing nanfu aluminum industry
Chongqing changjiang normal university
Chongqing vocational and technical college of industry
and trade
Chongqing university
Chongqing jiaotong university
Chongqing rail transit group
Chongqing electromechanical group
Chongqing changan group
Chongqing iron and steel group longevity production base
construction project
Chongqing wanda sheet fuling production base
Chongqing leading port construction project
Chongqing fuling gaishan bay traffic hub
Chongqing fuling sewage treatment plant
Sichuan guangyuan sewage treatment plant
 
Reception of Foreign Merchants

 
Product Tag:
Related categories:
Scroll to Top