Sw500 Ophthalmic Equipment Portable

Min.Order: 1
Product origin: Yangzhou, Jiangsu, China
Infringement complaint: complaintComplaint
US$ 1399

Description

Model: SW-500

China SW-500 Portable Rebound Tonometer, Portable Tonometer With Wireless Printer tonometer

 

Product Description

rebound tonometer , portable tonometer 

With vertical and horizontal two working modes, wireless output print data.

 

The equipment is used to measure intraocular pressure, using the principle of: the probe hits the surfaces of different hardness at a certain speed, has different reaction when the probe rebounds. 

 

Be of advantages of high accuracy, portable, without anesthesia, without the cross-infection etc.

 

Use a very light probe to contact the cornea at the monent to measure intraocular pressure accurately. And patients hardly feel the measure, so which does not cause corneal reflex usually.

 

Features :

  • 1.It`s a handset device: small, portable and proven to be accurate by several independent clinical studies, which also confirms the exceptional user and patient friendliness of this device
  • 2.The probe has very less contact with patient, avoiding discomfort reaction.
  • 3.Automatic exist function of probe
  • 4.Easy and fast measuring with outstanding accuracy and consistency without the need of anesthesia
  • 5.One-time use of the probe to avoid cross-infection
  • 6.Measurement can go along both in standing and lying posture
  • 7.Wireless data printing
  • 8.Esay to learn ,easy to use
  • 9.Lightweight and handy
  • 10.No anesthesia, avoiding discomfort reaction

 

 

 

Best Price SW-500 Portable Handheld Rebound Tonometer 

Features:
1. It`s a handset device: small, portable and proven to be accurate by several independent clinical studies, which also confirms the exceptional user and patient friendliness of this device
2. The probe has very less contact with patient, avoiding discomfort reaction.
3. Automatic exist function of probe
4. Easy and fast measuring with outstanding accuracy and consistency without the need of anesthesia
5. One-time use of the probe to avoid cross-infection
6. Measurement can go along both in standing and lying posture
7. Wireless data printing
8. Esay to learn,easy to use
9. Lightweight and portable
10. No anesthesia, avoiding discomfort reaction

Specifications: 

Measure Range

3mmHg~70mmHg

Measure Error

±1.5mmHg(3mmHg≤intraocular pressure≤25mmHg)

±2.5mmHg(25mmHg

Transport and Storage

Ambient temperature

-20ºC~+55ºC

Relative moisture

≤95%

Atmosphere pressure

500hPa~1060hPa

Running

Ambient temperature

+5ºC~+40 ºC

Relative moisture

≤80%

Atmosphere pressure

700hPa~1060hPa

Rating voltage

DC3V(2 AA Batteries)

Rating input power

1VA