1) Rolling steel;
2) Titanium alloy material;
3) Refractory material production;
Features:
1) Easy Installation: fixing on the machine, aiming at the rolling steel, directly measure the temperature during the rolling process.
2) Accurate measurement: Ratiometric measuring make sure overcome the influence of dust, smoke, water vapour, a small amount of steel slag and other factors, accurately measure the temperature of rolling steel.
Especially, during rolling, quickly oxidized on the metal surface to form an oxide layer, the layer shed or crack with the change of temperature. The gap between the oxide skin and the metal body formed, making the temperature of the oxide layer lower than the metal body.
Through special wavelength selection and software algorithm processing, the Ratiometric measuring thermometer can overcome the error caused, get reliable data for process analysis.
3) Little maintenance: protected in a strong stainless steel case to resist harsh working environment, durable.
4) Convenient management: special software for thermal field, centralized data management in different factories and production lines. Palm management, and multi-terminal visualization. Customized accepted based on user requirements, quality check, inspection, statistics and other functions.
Working Method:
Item | Description | |
1 | Visual targeting system | --check it aligned to the target or not; --If sealed environment, visual aiming also be used as a window to observe the working status; --no limitation for measuring distances |
2 | analog output | 0-5V/0-20mA/4-20mA |
3 | Digital output | RS485(optional) |
4 | Working method | Single color/ two color (alternative) |
Item | Parameter | |
1 | Measurement range | 800-1800ºC |
2 | Spectral range | 0.8-1.1µm/ 0.4-1.1µm |
3 | Distance-to-Spot Ratio (D:S) | 280:1 |
4 | Accuracy | ±0.75%(FS) |
5 | Repeatability | 0.2% |
6 | Response time(95%) | ≤5ms |
7 | Temperature resolution(analog) | 0.5ºC |
8 | Temperature resolution(digital) | 0.1ºC |
9 | Output | 0-20mA/4-20mA/0-5V |
10 | Power | 24VDC,100mA |
11 | Ambient temperature range | 0-70ºC |
12 | With air cooling | 120ºC |
13 | With water cooling | 175ºC |
14 | Storage temperature range | -20-70ºC |
15 | Dimensions | L:max185mm; Φ58mm |
16 | Vibration | GB/T2423.8-1995 |