Duplex AAC/ACSR Conductor Overhead Power Transmission Used XLPE Twisted ABC Power Cable

Min.Order: 2,000
Product origin: Zhengzhou, Henan, China
Infringement complaint: complaintComplaint
US$ 2.68 ~ 2.88

Description

Duplex AAC/ACSR Conductor Overhead Power Transmission Used XLPE Twisted ABC Power Cable

Application

Aerial Bundle Cable (ABC cable) is a very innovative concept for overhead power distribution as compared to the conventional bare conductor overhead distribution system.

It provides higher level of safety and reliability, lower power losses and ultimate system economy by reducing installation, maintenance and operative cost.

Caledonian LV Aerial Bundle Cables are designed to supply 600/1000 volt aerial service for temporary service at construction sites, as a service drop (power pole to service entrance), as a secondary cable (pole to pole) or street lighting.

This over-head cable provides reinforced insulation acc. IEC 61140 and fulfill therefore Class II acc. IEC 61140. It is not flame retardant. But this could be if requested change to a flame retardant cable.

Standard

Basic design to BS 7870 / TNB Specification(IEC 60502) / HD 626 S1 / NFC 33-209 / AS/NZS 3560-1 standards

Construction

  
ConductorAluminium conductor, round stranded compressed (RM).1350 aluminum wire
InsulationXPLE compound, UV-resistant.
Core Identification1, 2 resp. 3 raised longitudinal ribs on the surface of the cores. The surface of the neutral core should have at least 12 ribs for cross-sections up to 50 mm^2 and a minimum of 16 ribs for cores above 50 mm^2. In the case of five core bundles the surface of the protective core should be smooth.

Electrical Properties

Rated Voltage0.6/1kV
Test Voltage4 Veff kV
Minimum Laying Temperature-20°C
Operating Temperature-40°C~ +90°C
Maximum Short-circuit Temperature250°C
Maximum Conductor Temperature80°C
Minimum Bending Radius18×OD

Construction Parameters

CODE* WORDPHASE CONDUCTORBARE NEUTRAL MESSENGERWEIGHT PER 1000 FT.(LBS.)ALLOWABLE AMPACITIES+
Size (AWGStrand- ingInsul. Thick. (mils)Equiv. Dia. (AWG)++Size++ (kcmil)Strand- ingRated Strength (lbs).XLPPOLYXLPPOLY
6201 ALLOY NEUTRAL-MESSENGER
Minex6145630.58711101011018570
Hippa6745630.58711101071078570
Prawn4145448.697176015215211590
Barnacle4745448.697176016016011590
Shrimp2745277.4772800243243150120
Gammarus1/07601/0123.374460390390205160
Leda1/09601/0123.374460384384205160
Dungenese2/07602/0155.475390483483235185
Cyclops2/011602/0155.475390474474235185
Flustra3/017603/0195.776790587587275215
Lepas4/018604/0246.978560728728315245
 

 

*Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Haiotis/XLP).

+Conductor temperature of 90°C for XLP, 75°C for Poly; ambient temperature of 40°C; emissivity 0.9; 2 ft./sec. wind in sun.

++Designated sizes are: ACSR 6/1 diameter equivalent and AAC with equivalent resistivity per ASTM B-399 for 6201.

CODE* WORDPHASE CONDUCTORBARE NEUTRAL MESSENGERWEIGHT PER 1000 FT. (LBS.)ALLOWABLE AMPACITIES+
Size (AWG)Strand- ingInsul. Thick. (mils)Equiv. Dia. (AWG)++Size (kcmil)Strand- ingRated Strength (lbs.)XLPPOLYXLPPOLY
6201 ALLOY REDUCED NEUTRAL-MESSENGER
Artemia4145630.587111013513511590
Crab4745630.587111014314311590
Solaster2745448.6971760216216150120
Sandcrab1/0760277.4772800347347205160
Echinus1/0960277.4772800341341205160
Fulgar3/017601/0123.374460519519275215
Arca4/018602/0155.475390643643315245
 

 

*Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Haiotis/XLP).

+Conductor temperature of 90°C for XLP, 75°C for Poly; ambient temperature of 40°C; emissivity 0.9; 2 ft./sec. wind in sun.

++Designated sizes are: ACSR 6/1 diameter equivalent and AAC with equivalent resistivity per ASTM B-399 for 6201.