GB/T 14678-93 Low-temperature gas concentration meterProduct Parameters
The FX-GCM-1D type is a low-temperature gas concentration meter is a concentration instrument that integrates sampling, concentration, desorption, sample injection, and cleaning. With a 7.0-inch intelligent color touch screen user interface, it can easily set or edit, store, and invoke methods, quickly start analysis, and make operation more convenient.
Application field:
Used for the determination of hydrogen sulfide, methyl mercaptan, methyl sulfide, and dimethyl disulfide in air quality. The relevant standards are GB/T 14678-93 Features
Features
Adopt electronic refrigeration method, without liquid refrigerant, with a focused cold trap;Sample injection valve, transfer tube, concentration tube (refrigeration, heating), separate temperature control;The six-way valve is driven by a motor;All sample transmission pipelines adopt imported high inert deactivation pipelines, without residue;The connection point between the six-way valve and the transmission pipeline is located in the heating insulation box, without transmission cold points;Integrated design, compact overall structure; Microcomputer control;Equipped with two universal drive interfaces, it can automatically start chromatography and work together with workstations;Equipped with two universal drive interfaces, it can automatically start chromatography and work together with workstations;Peripheral devices are ready for signal input and can intelligently judge and analyze events;It can be connected to most gas chromatographs from various manufacturers at home and abroad for gas chromatograph mass spectrometry;Upgradeable PC software reverse control;Automatic gas injector can be installed.Technical Specifications
Specifications
The heating temperature of the injection valve components. Controllable temperature range: | room temperature~300 ºC, with an increment of 1 ºC. |
The heating temperature of the transfer tube. Controllable temperature range: | room temperature~300 ºC, with an increment of 1 ºC. |
The cooling temperature of the cold well during cold well adsorption. Controllable temperature range: | - 40 ºC to room temperature, with an increment of 1 ºC. |
The heating temperature of the cold well during cold well desorption. Controllable temperature range: | room temperature~400 ºC, with an increment of 1 ºC. |
Heating temperature during cold well activation. Controllable temperature range: r | oom temperature~400 ºC, with an increment of 1 ºC. |
The time used for cold well adsorption | 0 to 300 minutes can be set in increments of 0.01 minutes. |
The time used for cold trap desorption, | 0 to 300 minutes can be set in increments of 0.01 minutes |
After cold trap desorption | 0 to 300 minutes can be set in increments of 0.01 minutes. |
The time required for sample analysis | 0 to 300 minutes can be set in increments of 0.01 minutes. |
Similar Testing Equipment
Company Profile
Who we areWe are professional manufacturer & supplier specialized in Civil Engineering & Material testing equipments since 2003. We can supply various kinds of testing equipments that complies to the following standards ASTM/AASHTO, ISO, EN, DIN JIS, as well as other specialized industry standards. Meanwhile we are authorized oversea market distributer of some famous China testing equipments manufacturer. Our customers come from 6 Continents with more than 90 countries & area since company has been established.
What we supply1. Soil testing equipment
2. Asphalt testing equipment
3. Cement testing equipment
4. Concrete test equipment
5. Material test machine
6. Aggregate testing equipment
7. Pavement test equipment
8. Geotextiles testing equipment
9. Non destructive testing equipment
10. Drilling fluids testing equipment
11. Rock mechanics testing equipment
12. General Laboratory equipment
- CONSTRUCTION MATERIAL TEST EQUIPMENT
- SERVE REAL INSTRUMENTS INTRODUCTION