Honeywell Flame Detector UV R7849A1098 Flame Detector Burners Parts Sensor Tester

Min.Order: 1
Product origin: Shenzhen, Guangdong, China
Infringement complaint: complaintComplaint
US$ 245 ~ 268

Description
Honeywell Flame Signal Amplifier R7849A1098 Ultraviolet Detector Application To Gas and Oil

Honeywell Flame Signal Amplifier R7849A1098 Ultraviolet Detector Application to Gas and Oil
The R7849A,B Ultraviolet Flame Amplifiers are solid state plug-in amplifiers that respond to an ultraviolet signal from a
C7027, C7035 or C7044 Ultraviolet Flame Detector to indicate the presence of flame when used with 7800 SERIES and
R7140 Relay Modules.
Name
Flame Signal Amplifier
Brand
Honeywell
Origin
America
After Warranty Service
Video technical support
Ultraviolet:
R7849A,B for use with C7027/C7035/C7044 Minipeeper Ultraviolet Detectors.

Honeywell Flame Signal Amplifier R7849A1098 Ultraviolet Detector Application To Gas and Oil

Features:
* Flame failure response time of 0.8 or 1 second; or 2.0 or 3.0 seconds, depending on the amplifier and relay
module selected. See Table 1.
* Plug-in to 7800 SERIES and R7140 Relay Module through printed circuit board edge connector keyed
for proper orientation.
* Flame signal test jacks measure amplifier flame signal voltage.
* 0.0 to 5.0 Vdc Flame signal strength reading range.
* Color coded label identifies flame detection type:
- Green-rectification. Red-infrared.
- Purple-ultraviolet. Blue-pulsed rectification.
- White-optical.
* R7847B, R7848B, R7849B Dynamic Ampli-Check® circuitry tests all flame amplifier components 12 times per minute. The 7800 SERIES and R7140 Relay Module
locks out on safety shutdown with amplifier failure.
* R7824C, R7847C Dynamic Self-Check Rectification Amplifier, R7851C Dynamic Self-Check Optical Flame
Amplifier, R7861 Self-Check Ultraviolet Flame
Amplifier and R7886A Dynamic Self-Check Ultraviolet
Amplifier test the detectors and all electronic
components in the flame detection system 12 times
per minute. The 7800 SERIES and R7140 Relay Module
locks out on safety shutdown with flame detection
system failure. NOTE: R7824C, Series 2 or greater and R7847C Series 4 or greater, pulse the shutter when signal of 1.5 Vac is sensed. Display readings of 0.7 to 2.4 Vdc are common.

 
SPECIFICATIONS
Models: Flame Detection Systems (see Table 2):
Rectification: R7824C for use with C7024E,F Solid State Ultraviolet
Detectors. R7847A,B for use with flame rods or C7012A,C Solid State
Ultraviolet Detectors. R7847C for use with C7012E, F Solid State Ultraviolet Detectors.
Honeywell Flame Signal Amplifier R7849A1098 Ultraviolet Detector Application To Gas and Oil