water purifier machine price industrial water purifier price Ro water machine price
Different source water have diffent TDS for compare and usage.
Raw water/ Application | Bottled water, Bag water | City tap water | Brackish water | Seawater |
TDS Range | 2-10ppm | 100-1000ppm | 2000-20000ppm | 20000-40000ppm |
Direct Drinking | Yes | Yes/No | No | No |
Cooking, human consumption, washing | Yes | Yes | No | No |
Irrigation, Industry, Animal Drinking | Yes | Yes | No | No |
Replacement time of consumable parts
There are several kinds of consumables you need to replace regularly, please see below detail.
a. Quartz sand: replaced about every 15-18 months. 50kg/bag
b. Activated carbon: replaced about every 15-18 months. 25kg/bag
c. Resin: replaced about every 15-18 months. 25L/bag
d. PP Filter cartridge: replaced about every 1 month
e. Ro membrane: replaced about every 2 year
The process of RO water treatment system (some process is option as per feed water quality)
Raw water pump→ mechanical filter(quartz sand filter)→ activated carbon filter→sodium-ion exchanger
(water softener)→ security filter→ high pressure pump →Reverse osmosis→ Ozone sterilizer (UV sterilizer).
RO Process steps introduction
Pre-treatment | Feed water pump, Stainless steel | Provide pressure for filters; |
Quartz sand filter | Remove suspended particle and large impurity. In this system; | |
Active Carbon Filter (option) | Remove the color, free chloride, organic matter, harmful matter, ect; | |
Anti-scalant system | To add chemicals to remove some impurities and prolong thememebranes using/washing time(prevent membrane blocking) | |
Manual/Auto control valves | Flushing sand/carbon filter after some time | |
5micron filter | Remove larger than 5 micro colloids in the water. In this system | |
1micron filter | Remove larger than 1 micro colloids in the water. In this system | |
water RO Main Part | High pressure pump, Stainless steel 316L | Provide the high pressure to RO membrane; |
Ro membranes | More than 98% desalination rate, can remove ions except H2O. | |
CIP system | To washing the membranes when it is blocked after using for long time | |
Electronic control panel | PC controller or PLC controller |
RO process flow chart: (Carbon filter softener based on feed water quality opiton)
Model | Productivity | Motor power | Recovery rate | Outlet water conductivity(us/cm) | Raw water conductivity |
HYRO-500L | 0.5T/H | 1.5kw | 50 | ≤10 | ≤300 |
HYRO-100L | 1T/H | 2.2kw | 50 | ≤10 | ≤300 |
HYRO-2000L | 2T/H | 3kw | 50-60 | ≤10 | ≤300 |
HYRO-3000L | 3T/H | 4.5kw | 55-65 | ≤10 | ≤300 |
HYRO-4000L | 4T/H | 6.5kw | 55-65 | ≤10 | ≤300 |
HYRO-5000L | 5T/H | 8kw | 60-70 | ≤10 | ≤300 |
HYRO-1000L | 10T/H | 15kw | 60-70 | ≤10 | ≤300 |
HYRO-2000L | 20T/H | 22kw | 65-75 | ≤10 | ≤300 |
HYRO-3000L | 30T/H | 26kw | 70-75 | ≤10 | ≤300 |
HYRO-50000L | 50T/H | 55kw | 70-75 | ≤10 | ≤300 |