Copper pipes are commonly used in the construction industry for residential water supply lines and sometimes for drain and vent lines. Copper pipes can be manufactured as soft or rigid copper and they offer excellent corrosion resistance and reliable connections. While Flexible PEX(cross-linked polyethylene) is now the more common choice for new installation and upgrades, copper pipe still has its place. It is considered a sturdier building material that has a longer lifespan-lasting up to 70 years. However, copper is about 60 percent more expensive than PEX, and it can be susceptible to cracking if the water inside the pipes is subject to freezing temperatures.
Commonly used copper pipes can be divided into the following types:
Copper condenser tube, crystallizer copper tube, air conditioning copper tube, various extruded, drawn (reverse extrusion) copper tubes, iron white copper tubes, brass tubes, bronze tubes, white copper tubes, beryllium copper tubes, tungsten copper tubes Tubes, phosphor bronze tubes, aluminum bronze tubes, tin bronze tubes, imported red copper tubes, etc.
Thin-walled copper tubes, capillary copper tubes, metal copper tubes, special-shaped copper tubes, small copper tubes, pen copper tubes, pen copper tubes, etc.;
According to the needs of users, we process and produce square and rectangular mold copper tubes, D-shaped copper tubes, eccentric copper tubes, etc. according to the drawings.
The three most common types of copper pipe used in residential and commercial construction are Type K, Type L, and Type M. A fourth type, used for drain-waste-vent, or DWV, piping, is found most often in some older homes.
Best for: Main water lines, underground installations.
Type K copper pipe has the thickest wall of all the common types. It is used for water distribution, fire protection, oil, HVAC, and many other applications in the construction industry. Type K pipe is available in rigid and flexible forms. It is recommended for main water lines and underground installations because its thickness helps it withstand the pressure from backfilled earth in trenches.
Type K copper pipe is usually identified by a green stamp. It is an expensive form of copper pipe, and thus is not commonly used for interior water supply pipes.
Best for: Interior branch water supply lines.
Type L copper pipe is used for interior plumbing, as well as for fire protection, and some HVAC applications. It is available in rigid and flexible forms. Type L is considered the most common type of copper piping, as it can be used in many more applications than Type K. Flexible Type L copper is the common choice for repairing or replacing old branch water lines. Type L also can be used outside the home where it will be directly exposed. Type L copper is thinner than Type K but thicker than type M.
Type L copper is usually identified by a blue stamp. This is the type that professional plumbers use for most indoor residential water supply lines.
Best for: Branch plumbing lines.
Type M copper pipe is thinner than both type K and L copper pipe. It is a common choice for repairs, replacements, and extensions to interior water supply lines. But Type M copper is not always allowed by plumbing codes in all areas, so check first with the local building authority. Where allowed, it is often favored for residential work because of its relatively low price-a thinner pipe wall means less copper and thus a lower price. It is a favorite of DIYers, who find it easy to cut and fit. But it is not available in a flexible form, as is type L.
Type M copper pipe is identified by red markings.
Best for: Occasionally used for DWV (drain-waste-vent) pipes.
Copper pipe for plumbing drains and vents was used in many old homes and commercial applications, but it has been all but replaced with PVC or ABS plastic pipe in modern construction. (For specific applications or uses, check your local code.) It is suitable only for above-ground applications and has a low-pressure rating; it cannot carry the water pressure of most municipal water supply systems.
DWV pipe usually has yellow markings to distinguish it from other types.
Copper plumbing pipe (often known as tubing) comes in several types based on the thickness of the walls in the pipe relative to the diameter of the pipe. As outlined above, selecting the right copper pipe is really just a matter of matching the thickness of the pipe walls to the needs of the application. Type K has the largest wall-thickness to pipe diameter ratio and is usually used for underground applications where extreme strength is needed. At the other end, DWV grade has the lowest wall-thickness to pipe diameter ratio, making it suitable only for drain and vent lines that are under no pressure at all. In between, Types L and M are the pipes most often used for standard pressurized water supply pipes.
When purchasing pipe, be aware that the actual outside diameter (OD) of rigid copper pipe is always 1/8 inch larger than the nominal size-how the pipe is labeled. For example, a 1/2-inch copper pipe has an outside diameter of 5/8 inch. It is true with all three common types pipe, K, L, and M.
The key difference between these three types of copper pipes is that Type K pipes have thicker walls compared to Type L, and Type L walls thickness is thicker than Type M. Therefore, the copper pipe wall thickness determines different working pressure and application for each type of pipe.
Standard | GB/T 1527-2006,JIS H3300-2006,ASTM B75M-02,ASTM B42-02, ASTM B111M-04,ASTM B395M | ||
ASTM | C10100,C11000,C12200,C21000,C22000,C23000,C24000,C26000, C27000,C26800,C27200,C27400,C28000,C36500,C33000,C35300, C35600,C36000,C38500,C44300,C46400,C52100,C54400,C62300, C65500,C67500,C67600,C86300,C90700,C93200,C95400 etc. | ||
EN | CuZn5,CuZn10,CuZn15,CuZn20,CuZn30,CuZn35,CuZn33,CuZn36, CuZn37,CuZn40,CuZn40Pb,CuZn37Pb2,CuZn36Pb3,CuZn39Pb3, CuZn28Sn1,CuZn38Sn1,CuSn8,CuSn4Pb4Zn3,CuSi3Mn,CuZn25Al5, CuSn10 | ||
GB | TU0, TU1,T2,TP2,H96,H90,H85,H80,H70,H65,H63,H62,H59,HPb63-3, HPb66-0.5,HPb62-2,HPb62-3,HPb59-3,HSn70-1,HSn62-1 | ||
Size | Ourside diameter 2 to 800mm ,wall thickness 0.1mm to 60mm Length 1meter to 6meter or according to client's request | ||
Hardness | 1/16 hard,1/8 hard,3/8 hard,1/4 hard,1/2hard,full hard. | ||
Surface | Polished,bright,oiled,hair line,brush,mirror,or as required | ||
Export to | Ireland,Singapore,Indonesia,Ukraine,Saudi Arabia,Spain,Canada,USA, Brazil,Thailand,Korea,Italy,India,Egypt,Oman,Malaysia,Kuwait,Canada, Viet Nam, Peru | ||
Package | Plastic film with Wooden case or wooden pallet | ||
Delivery time | Prompt delivery or upon your order quantity. | ||
MOQ | Negotiable | ||
Quality Control | Mill Test Certification is supplied with shipment,Third Part Inspection is acceptable. | ||
Application | widely used inair conditioners,refrigerators,electric,solar water heater, polished pipe an be used in decorative,such as stair rail. Also can be made according to your required. | ||
Shape | Round, Square, Flat, Hexagon, Oval |
ASTM | DIN | GB | JIS |
C10100 | _ | TU0 | C1011 |
C10200 | OF-CU | TU1 | C1020 |
C11000 | SE-CU | TU2 | C1020 |
C12000 | SW-CU | T1 | C1201 |
C12000 | SF-CU | TP1 | C12 |
Nominal Pipe Size inches | O.D. | I.D. | Wall Thickness | ||||||
Type | |||||||||
K* | L** | M*** | DWV**** | K | L | M | DWV | ||
1/4 | 0.375 | 0.305 | 0.315 | - | - | 0.035 | 0.030 | - | - |
3/8 | 0.500 | 0.402 | 0.430 | 0.450 | - | 0.049 | 0.035 | 0.025 | - |
1/2 | 0.625 | 0.527 | 0.545 | 0.569 | - | 0.049 | 0.040 | 0.028 | - |
5/8 | 0.750 | 0.652 | 0.666 | - | - | 0.049 | 0.042 | - | - |
3/4 | 0.875 | 0.745 | 0.785 | 0.811 | - | 0.065 | 0.045 | 0.032 | - |
1 | 1.125 | 0.995 | 1.025 | 1.055 | - | 0.065 | 0.050 | 0.035 | - |
1-1/4 | 1.375 | 1.245 | 1.265 | 1.291 | 1.295 | 0.065 | 0.055 | 0.042 | 0.040 |
1-1/2 | 1.625 | 1.481 | 1.505 | 1.527 | 1.541 | 0.072 | 0.060 | 0.049 | 0.042 |
2 | 2.125 | 1.959 | 1.985 | 2.009 | 2.041 | 0.083 | 0.070 | 0.058 | 0.042 |
2-1/2 | 2.625 | 2.435 | 2.465 | 2.495 | - | 0.095 | 0.080 | 0.065 | - |
3 | 3.125 | 2.907 | 2.945 | 2.981 | 3.030 | 0.109 | 0.090 | 0.072 | 0.045 |
3.5 | 3.625 | 3.385 | 3.425 | 3.459 | - | .120 | .100 | .083 | - |
4 | 4.125 | 3.857 | 3.897 | 3.935 | 4.009 | .134 | .114 | .095 | .058 |
5 | 5.125 | 4.805 | 4.875 | 4.907 | 4.981 | .160 | .125 | .109 | .072 |
6 | 6.125 | 5.741 | 5.845 | 5.881 | 5.959 | .192 | .140 | .122 | .083 |
8 | 8.125 | 7.583 | 7.725 | 7.785 | - | .271 | .200 | .170 | - |
*K: thick walled, underground residential, commercial and industrial uses. **L: medium walled, residential and commercial uses ***M: thin walled, above ground residential and light commercial uses. ****DWV:Drain/Waste/Vent, non-pressurized |
Material | GB | ASTM | BS | DIN | Eu | JIS |
Copper Nickel | BFelO-1-1 | C70600 | CN 102 | CuNilOFelMn | CuNilOFelMn | |
C70610 | CN 102 | CuNilOFelMn | CuNilOFelMn | |||
BFe3O-I-I | C71500 | CuNi30Fe | C7150 | |||
CN107 | CuNi30Mnl Fe | CuNi30MnlFe | ||||
C71640 | CN 106 | CuNi30 | CuNi30 | |||
Fe2Mn2 | Fe2Mn2 | |||||
aluminum brass | HA177-2 | C68700 | CZ110 | CuZn20Al2 | CuZn20Al2As | C6870 |
Admiraltybrass | HSn70-I | C41100 | ||||
C44300 | CZ111 | CuZn28Snl | CuZn28Snl As | C4430 | ||
C44500 | ||||||
Copper | T2 | Cl 1000 | C102 | E-Cu58 | Cu-ETP | Cl 100 |
Tpl | Cl 2000 | SW-Cu | Cu-DLP | C1201 | ||
Tp2 | Cl 2200 | C106 | Cu-DHP | Cl 220 |
Material | GB | ASTM | BS | DIN | EU | JIS |
Tinbrass | HSn62-1 | C46200 | CZ112 | C4620 | ||
C46420 | C4642 | |||||
Aluminumbrass | HAI66-6-3-2 | C67000 | ||||
Admiraltybrass | HSn70-1 | C44300 | CZ111 | CuZn28Sn1 | CuZn28Snl As | C4430 |
Material | GB | ASTM | BS | DIN | Eu | JIS |
Brasstube | H96 | C21000 | CZ125 | CuZn5 | CuZn5 | C2100 |
H90 | C22000 | CZ101 | CuZnIO | CuZnIO | C2200 | |
H85 | C23000 | CZ102 | CuZnl5 | CuZnl5 | C2300 | |
H80 | C24000 | CZ103 | CuZn20 | CuZn20 | C2400 | |
Aluminumbronze | Qal5 | C60600 | CA101 | CuAl5 | CuAI5 | |
C60800 | ||||||
Qal7 | C61000 | CAI 02 | CuAl8 | CuAl8 | ||
Cupronickel | B19 | C71000 | CN104 | CuNi20Fe | C7100 | |
C70600 | CuNilOFe | C7060 | ||||
BZn15-20 | C75400 | NS 105 | CuNil8Zn20 | CuNil8Zn20 | C7521 | |
C75700 | CuNil2Zn24 | CuNil2Zn24 |
Material | GB | ASTM | BS | DIN | Eu | JIS |
Brasstube | H70 | C26000 | CZ 106 | CuZn30 | CuZn30 | C2600 |
H70A | C26130 | CZ 126 | CuZn3OAs | |||
H68 | C26200 | CuZn33 | CuZn33 | |||
C26800 | C2680 | |||||
H65 | C27000 | CZ 107 | CuZn36 | CuZn36 | C2700 | |
H63 | C27200 | CZ 108 | CuZn37 | CuZn37 | C2720 | |
C27400 | ||||||
H62 | C28000 | CZ 109 | CuZn40 | CuZn40 | C2800 | |
Aluminum brass | HA177-2 | C68700 | CA 110 | CuZn20Al2 | CuZn20Al2As | C6870 |
Tinbronzetube | Qsn6.5-0.1 | C51900 | CuSn6 | |||
CuSn8 | ||||||
Copper Nickel | BFelO-1-1 | C70600 | CN 102 | CuNilOFelMn | CuNilOFelMn | |
C70610 | CN 102 | CuNilOFelMn | CuNilOFelMn | |||
BFe30-I-1 | C71500 | CuNi30Fe | C7150 |