Xhlj504L Factory Price Xzh Test Underground Cable Path Meter for Detecting Direction and Path

Min.Order: 1
Product origin: Xi'an, Shaanxi, China
Infringement complaint: complaintComplaint
US$ 900 ~ 1200

Description

Product description

XHLJ504L cable route tracer (underground cable pipe locator) is a special instrument used to accurately detect the direction and depth of buried cables within a certain range;

The path detection is completed by the cooperation test of the path signal generator and the path signal receiver; through the cooperative operation between them, the cable path can be accurately positioned within the approximate cable buried range.
 

The main components of path detection

Path detection is mainly composed of path signal generator and receiver
 

Path signal generator
The path signal generator can generate high-power audio output signals, and the receiver receives the audio signals to complete the path detection function.
The main technical indicators are as follows:
a) Large output power, strong anti-vibration and anti-interference ability, stable and reliable;
b) It has reliable over-current, open-circuit, and short-circuit protection functions;
c) Output frequency: audio;
d) Output signal: intermittent, 0~50Vpp
e) Working power supply: 220V (1±10%) 50Hz (1±5%);
f) Output power: 100W;
g) Output current: 0~2A;
The path signal generator uses 220V mains power supply, and the output signal voltage and power vary with different loads. If the output terminal is short-circuited, the device will be protected immediately. After the load short-circuit state is eliminated, press the start button and the device will resume normal operation.

Path receiver
The panel is equipped with a power button, a volume increase button ( "+"), a volume decrease button ("-"), and a sound outlet. Press and hold the power button for 5 seconds to complete the power on/off operation, and use "+" and "-" to complete the volume adjustment. The display part uses a semi-circular LED bar to display the current signal strength, and 4 LEDs to indicate the battery level.

 technical datas
 Output Frequency
Audio Frequency.
Output signal
intermittent,0~50Vpp
Power supply
220V(1±10%) 50Hz(1±5%)200mA
Output power
100W
Output current
0~2A
 Receiving mode
electro-magnetic induction

That is to say, when detecting the direction of the cable path, the probe and the horizontal plane should always be kept vertical. When the probe is directly above the cable direction, the received sound is relatively the smallest, and the ground position connection with the smallest relative indication is the cable path to be tested. the direction of the location.
In addition, when detecting the buried depth of the cable path, the probe should be perpendicular to the cable and the angle between the probe and the horizontal plane should be 450. When moving the probe to one side, the sound will change from large to small, and then from small to large. Relative indication The vertical distance from the point on the smallest ground to the ground of the cable is the buried depth of the cable there.

---------------------------------------------------------------------------------------------------------------------------------------------------------

 

 

 













Product Tag:
Related categories:
Scroll to Top