Type | Code | Explanation | |||||
MD3051 | Online density meter | ||||||
Installation | A | Top mounted | |||||
B | Bend type | ||||||
C | Side mounted | ||||||
Diaphragm material | L | 316L | |||||
H | HC | ||||||
T | Tantalum | ||||||
Sensor spacing | 5 | 500mm | |||||
8 | 800mm | ||||||
F | Other requirements | ||||||
Density range | 1 | 0-1g/cm3 | |||||
2 | 0-2g/cm3 | ||||||
3 | 0-3g/cm3 | ||||||
Connection type | F | Flange | |||||
C | Clamp type | ||||||
The following is the default configuration: | |||||||
Display | LCD display | ||||||
Output | 4-20mA | ||||||
Power supply | 24VDC | ||||||
Package | wooden case |
Technical specifications
Measurement Range: | Density: 0.000 - 5.000 g/cm31 |
Accuracy: | Density 0.5-2 g/cm3 |
Resolution: | ±0.005 g/cm3 |
Calibration Method: | User performed |
Temperature Range (Sample): | 0 - 100 °C (32 - 212 °F) |
Communication: | 4 - 20 mA, HART Protocol |
Display: | Digital LCD |
Operating Environment: | Temperature: -10 - 60°C (14 - 140°F) |
Power Requirements: | 15 - 30 VDC (24 VDC recommended) |
Dimensions: | Individual dimensions vary depending on model, volumetric displacement no more than 0.15 cm3 (0.01 in3) |
(1) Listed total range, specific models ordered with range of 0-1, 0-2, or 0-3 g/cm3.
(2) DM-1000C tolerates higher temperature range of sample due to installation method.