1phase 220V 2.2kw Solar Frequency Pumping Power Inverter

Min.Order: 1
Product origin: Suzhou, Jiangsu, China
Infringement complaint: complaintComplaint
US$ 46 ~ 50

Description
 
inputRated voltage,frequencyThree phase (4T Series) 380V; 50 / 60Hz three phase (2t Series) 220V: 50 / 60Hz
Allowable variation range of voltageThree phase (4T Series) 320v ~ 460V three phase (2t Series) 190V ~ 250V
outputVoltage4T series; 0 ~ 380V 2T series; 0 ~ 220V
frequency0~600HZ
Overload capacity110% long term 150% 1 minute 180% 5 seconds
control modeV / F control, simple vector control
Control characteristicsFrequency setting resolutionAnalog input0.1% of maximum output frequency
Digital setting0.1HZ
Frequency accuracyAnalog inputWithin 0.2% of maximum output frequency
Digital inputSet the output frequency within 0.01%
V/F controlV / F curve (voltage frequency characteristic)The reference frequency can be set arbitrarily from 5 Hz to 600 Hz, the multi point V / F curve can be set arbitrarily, and a variety of fixed curves such as constant torque, low reduced torque 1, low reduced torque 2 and square torque can also be selected
Torque liftingManual setting: 0.0 ~ 30.0% of rated output
Automatic lifting: according to the output current and motor parameters, automatically determine the lifting torque
Automatic current limiting and voltage limitingWhether in the process of acceleration, deceleration or stable operation, the stator current and voltage of the motor are automatically detected, and the unique algorithm is used to suppress the current and voltage within the allowable range, so as to minimize the possibility of system fault tripping
Control characteristicsSensorless vector controlVoltage frequency characteristicThe output voltage frequency ratio is automatically adjusted according to the motor parameters and unique algorithm
Torque characteristicsStarting torque:
100% rated torque at 5.0hz (VF control)
150% rated torque at 1.5Hz (simple vector control)
Current and voltage suppressionFull range current closed-loop control, completely avoid current impact, with perfect over-current and over-voltage suppression function
Under voltage suppression in operationEspecially for the users with low grid voltage and frequent fluctuation of grid voltage, the system can maintain the longest possible operation time according to the unique algorithm and residual energy allocation strategy even if the voltage is lower than the allowable range
Typical functionsMulti speed operation7-segment programmable multi-stage speed control, multiple operation modes are optional.
PID controlBuilt in PID controller (preset frequency). Standard configuration of RS485 communication function, a variety of communication protocols optional, with linkage synchronization control function
RS485 communication
Frequency settingAnalog inputDC voltage 0 ~ 10V, DC current 0 ~ 20mA (upper and lower limit optional)
Digital inputOperation panel setting, RS485 interface setting, up / DW terminal control, and various combination settings with analog input
output signalDigital output1 channel OC output and 1 channel fault relay output (TA, TB, TC), up to 14 meaning options
Analog outputOne analog signal output, the output range is 0 ~ 20mA or 0 ~ 10V, which can realize the output of physical quantity such as setting frequency and output frequency
Automatic stable operationAccording to the needs, dynamic voltage stabilization, static voltage stabilization and non voltage stabilization can be selected to obtain the most stable operation effect
Acceleration and deceleration time setting0.1s ~ 999.9min continuous setting
brakingEnergy consumption brakingThe starting voltage, return differential voltage and energy consumption braking rate can be adjusted continuously
DC brakeStarting frequency of DC braking at shutdown: 0.00 ~ [f0.05] upper limit frequency
Braking time: 0.0 ~ 30.0S; braking current: 0.0% ~ 50.0% of motor rated voltage
Low noise operationCarrier frequency 1.0khz ~ 16.0khz can be adjusted continuously to minimize motor noise
CounterOne internal counter, convenient for system integration
Operation functionSetting of upper and lower frequency, frequency jump operation, reverse operation limit, slip frequency compensation, RS485 communication, frequency increasing, decreasing control, fault self recovery operation, etc
displayOperation panel displayrunning stateOutput frequency, output current, output voltage, motor speed, set frequency, module temperature, PID setting, feedback, analog input and output, etc
Alarm contentOutput frequency, set frequency, output current, output voltage, DC voltage, module temperature and other operating parameters recorded during the last fault trip
Protection functionOver current, over voltage, under voltage, module failure, electronic thermal relay, overheating, short circuit, internal memory failure, etc
Environmental ScienceAmbient temperature- 10 ºC~ + 40 ºC (if the ambient temperature is between 40 ºC and 50 ºC, please reduce the rating for use)
Ambient humidity5% - 95% RH, no water condensation
surrounding environmentIndoor (no direct sunlight, corrosion, flammable gas, oil mist, dust, etc.)
altitudeDerating for more than 1000m, with 10% derating for every 1000m increase
structureProtection levelIP20
Cooling modeAir cooled with fan control
Installation modeWall mounted, cabinet

 
Overall dimensionsThe size of holeThe thickness of the
WHW1H1D
104.476.398.267.522

b.Overall dimension
0.75KW-2.2KW/220V  1.5KW-4.0KW/380V
 
Voltage gradespecificationspower(kW)Overall dimensions(mm)Installation dimensions(mm)Packing size(mm)
The net weight(kg)
W1H1DW2H2φlongwideheight
220VSingle phaseM300-2SR75G/1.5P0.7595.5158.5132.583.51454.51951321721.23
M300-2S01R5G/2.2P1.5
M300-2S02R2G/4P2.2

Superior performance, can achieve 4 control modes

The highest operating frequency HKUST 3000HZ

Automatic slip compensation-more accurate speed

Excellent torque output: 150% rated torque at 3.0HZ (VF control)

0.5HZ180% rated torque (current vector control)

High overload capacity-150% rated torque can last for 60 seconds

Ultra-low noise, the carrier frequency can be adjusted between 1-16K (set by model)

Timely and reliable control and protection, high system stability

Product Features:

1. Can be equipped with LCD panel, dual-line digital tube panel, single-line digital tube panel

2. Pulse train I/O function

3. Running time and power consumption record

4. Speed and torque control

5. Separate VF control

6. Swing frequency control

7. Fixed length control

8. PID control air energy

9. Communication function

10. The panel has a parameter copy function


Product Tag:
Related categories:
Scroll to Top