Bluetooth and Touch Screen Ambulance Medical Patient Monitor

Min.Order: 1
Product origin: Shenzhen, Guangdong, China
Infringement complaint: complaintComplaint
US$ 380 ~ 425

Description
 
RSD5000

Introduction:
  1. All-in-one designed module with 5 standard parameters: ECG, NIBP, SPO2, Pulse Rate and Temperature
  2. Optional parameter: ETCO2
  3. This machine can meet all requirements, and meet requirements of hospital & other departments in emergency treatment, first-aid, rescue,etc.
Function:
  1. Touch screen, 5.0 inch color TFT LCD, simple for operating, quickly & accurately measure the data;
  2. Build-in rechargeable Li-battery(7200mAh 3.7V), up to 15hours running time, support AC and DC power;
  3. Adjustable audible and visual alarms, and sensor off alarm;
  4. Long time monitoring and sleeping monitoring;
  5. Easy to carry, suitable for ambulance center, has the stand for fixing;
Prior:
  1. Storage and review data up to 9999 user ID and 3888groups via Trend Graph and Trend List.
  2. Bluetooth data upload to Android mobile
  3. Big font screen interface is easy to observe;
  4. Back light can be adjusted;
Specification:
1. General Specifications:
Size: 209mm×104mm×47.5mm
Net Weight: 655g
Display Specification
Measurement Display: color TFT- LCD/touch screen
Power Supply Indicator: Dual-color LED (red/green)
Charging indicator: A green LED
2. Power Supply
AC Power Adaptor
Input: 100~240V AC, 50/60Hz, 0.7A
Output: DC 5V, 2A
Battery

Li-ion rechargeable battery, 3.7V/7200mAH
Operating Time: 15 hours with full battery capacity.
(Condition: 25ºC, NIBP working period is 15 minutes)
Recharge Time: 10 hours.
3. Environment
Temperature
Working:0ºC~45ºC
Transport and Storage: -25ºC~85ºC
Humidity
Working:30%~85 %
Transport and Storage: 30%~95 % (no condensation)
4. Monitoring Parameter
ECG
Input:5-lead ECG cable, standard AAMI cable connector
Lead Selection:I,II,III, avR,avL,avF,C
Gain Selection:×1,×2,×4,×8
Sweep Speed: 12.5, 25, and 50 mm/s
Frequency Response: None filter: 0.05~100Hz (-3dB), filter: 0.5~40Hz (-3dB)
Calibration Signal: 1mV square wave
Heart Rate
Measuring Range: 20 bpm~300 bpm
Renew Time: 1 time per beat
Accuracy:±1 bpm
Alarm Mode: Audible and visual alarm
SpO2
SpO2%
Measuring Range:0%~100%
Resolution:1 %
Accuracy:±2 %(90%~99%), ±3 %(70%~89%),unspecified (0%~69%)
Pulse Rate
Measuring and Alarm Range:20~300bpm
Resolution:1bpm
Accuracy:±1bpm
NIBP
Method: Oscillometric
Mode: Manual, Auto, STAT
Measuring Interval in AUTO Mode: 1, 2, 3, 5, 10, 15, 20, 30, 45, 60 (min)
Measuring Period in STAT Mode: 5 min
Cuff Pressure Range:0 mmHg~300mmHg
Pulse Rate Range:30 bpm~250bpm
Measurement Rage: Adult 30 mmHg~255mmHg, Pediatric 30 mmHg~160mmHg
Over-pressure Protection: Adult 300mmHg, Pediatric 220mmHg
Pressure Resolution: 1mmHg
The SYSTOLIC and DIASTOLIC values measured using this device shall be equal to those measured by trained medical personnel using cuff and stethoscope. The MAP value measured using this device is equal to that measured using blood pressure measurement device.
Temperature
Input: Body surface thermal-sensitive resistor temperature sensor
Measuring Range: 0ºC~50ºC
Accuracy: ±0.1ºC
EtCO2(Optional)
Measuring Range: 0~150mmHg
Resolution: 1 mmHg
Accuracy: ±2mmHg@< 5.0% CO2
Respiration Rate(Optional)
Measuring Range: 0~120rpm
Resolution: 1rpm
Accuracy: ±1rpm
5. Storage and Review
Maximum Data Quantity: 3888 groups
Maximum Trend Time: Continuous 129.6 hours
Standard accessories
main unit1
5lead ECG cable with TEMP sensor 1
NIBP cuff for adult with extend tube 1
SpO2 adult finger probe1
AC charger1
User manual in English1
 