All-in-one designed module with 5 standard parameters: ECG, NIBP, SPO2, Pulse Rate and Temperature.
Optional parameter: ETCO2
This machine can meet all requirements, and meet requirements of hospital & other departments in emergency treatment, first-aid, rescue,etc.
Function:
Touch screen,5.0 inch colorTFT LCD, simple for operating, quickly&accurately measure the data;
Build-in rechargeable Li-battery(7200mAh 3.7V), up to 15hours running time, support AC and DC power;
Adjustable audible and visual alarms, and sensor off alarm;
Long time monitoring and sleeping monitoring;
Easy to carry, suitable for ambulance center, has the stand for fixing;
Prior:
Storage and review data up to 9999 user ID and 3888groups via Trend Graph and Trend List.
Bluetooth data upload to Android mobile
Big font screen interface is easy to observe;
Back light can be adjusted;
Specification: 1. General Specifications: Size: 209mm×104mm×47.5mm Net Weight: 655g Display Specification Measurement Display: color TFT- LCD/touch screen Power Supply Indicator: Dual-color LED (red/green) Charging indicator: A green LED 2. Power Supply AC Power Adaptor Input: 100~240VAC, 50/60Hz, 0.7A Output: DC 5V, 2A Battery Li-ion rechargeable battery, 3.7V/7200mAH Operating Time: 15 hours with full battery capacity. (Condition: 25ºC, NIBP working period is 15 minutes) Recharge Time: 10 hours. 3. Environment Temperature Working:0ºC~45ºC Transport and Storage: -25ºC~85ºC Humidity Working:30%~85 % Transport and Storage: 30%~95 % (no condensation) 4. Monitoring Parameter ECG Input:5-lead ECG cable, standard AAMI cable connector Lead Selection:I,II,III, avR,avL,avF,C Gain Selection:×1,×2,×4,×8 Sweep Speed: 12.5, 25, and 50 mm/s Frequency Response: None filter: 0.05~100Hz (-3dB), filter: 0.5~40Hz (-3dB) Calibration Signal: 1mV square wave Heart Rate Measuring Range: 20 bpm~300 bpm Renew Time: 1 time per beat Accuracy:±1 bpm Alarm Mode: Audible and visual alarm SpO2 SpO2% Measuring Range:0%~100% Resolution:1 % Accuracy:±2 %(90%~99%), ±3 %(70%~89%),unspecified (0%~69%) Pulse Rate Measuring and Alarm Range:20~300bpm Resolution:1bpm Accuracy:±1bpm NIBP Method: Oscillometric Mode: Manual, Auto, STAT Measuring Interval in AUTO Mode: 1, 2, 3, 5, 10, 15, 20, 30, 45, 60 (min) Measuring Period in STAT Mode: 5 min Cuff Pressure Range:0 mmHg~300mmHg Pulse Rate Range:30 bpm~250bpm Measurement Rage: Adult 30 mmHg~255mmHg, Pediatric 30 mmHg~160mmHg Over-pressure Protection: Adult 300mmHg, Pediatric 220mmHg Pressure Resolution: 1mmHg The SYSTOLIC and DIASTOLIC values measured using this device shall be equal to those measured by trained medical personnel using cuff and stethoscope. The MAP value measured using this device is equal to that measured using blood pressure measurement device. Temperature Input: Body surface thermal-sensitive resistor temperature sensor Measuring Range: 0ºC~50ºC Accuracy: ±0.1ºC EtCO2(Optional) Measuring Range: 0~150mmHg Resolution: 1 mmHg Accuracy: ±2mmHg@< 5.0% CO2 Respiration Rate(Optional) Measuring Range: 0~120rpm Resolution: 1rpm Accuracy: ±1rpm 5. Storage and Review Maximum Data Quantity: 3888 groups Maximum Trend Time: Continuous 129.6 hours