Model | SUN-3.6K-SG03LP1-EU | SUN-5K-SG03LP1-EU | SUN-6K-SG03LP1-EU |
Battery Input Data | |||
Battery Type | Lead-acid or Lithium-ion | ||
Battery Voltage Range (V) | 40~60V | ||
Max. Charging Current (A) | 90A | 120A | 135A |
Max. Discharging Current (A) | 90A | 120A | 135A |
Charging Curve | 3 Stages / Equalization | ||
External Temperature Sensor | Optional | ||
Charging Strategy for Li-Ion Battery | Self-adaption to BMS | ||
PV String Input Data | |||
Max. DC Input Power (W) | 4680W | 6500W | 7800W |
PV Input Voltage (V) | 370V (125V~500V) | ||
MPPT Range (V) | 150~425V | ||
Full Load DC Voltage Range | 300~425V | ||
Start-up Voltage (V) | 125V | ||
PV Input Current (A) | 13A+13A | ||
Max. PV ISC (A) | 17A+17A | ||
No.of MPPT Trackers | 2 | ||
No.of Strings Per MPPT Tracker | 1+1 | ||
AC Output Data | |||
Rated AC Output and UPS Power (W) | 3600W | 5000W | 6000W |
Max. AC Output Power (W) | 3690W | 5500W | 6600W |
Peak Power (off grid) | 2 times of rated power, 10 S | ||
AC Output Rated Current (A) | 16.4A | 22.7A | 27.3A |
Max. AC Current (A) | 18A | 25A | 30A |
Max. Continuous AC Passthrough (A) | 35A | 40A | |
Power Factor | 0.8 leading to 0.8 lagging | ||
Output Frequency and Voltage | 50/60Hz; 220/230 / 240Vac (single phase) | ||
Grid Type | Single Phase | ||
Current Harmonic Distortion | THD<3% (Linear load<1.5%) | ||
Efficiency | |||
Max. Efficiency | 97.60% | ||
Euro Efficiency | 96.50% | ||
MPPT Efficiency | 99.90% | ||
Protection | |||
PV Input Lightning Protection | Integrated | ||
Anti-islanding Protection | Integrated | ||
PV String Input Reverse Polarity Protection | Integrated | ||
Insulation Resistor Detection | Integrated | ||
Residual Current Monitoring Unit | Integrated | ||
Output Over Current Protection | Integrated | ||
Output Shorted Protection | Integrated | ||
Output Over Voltage Protection | Integrated | ||
Surge protection | DC Type II / AC Type | ||
Certifications and Standards | |||
Grid Regulation | VDE 0126, AS4777, NRS2017, G98, G99, IEC61683, IEC62116, IEC61727, RD1699: 2011, XP C15-712-3: 2019-05 | ||
Safety Regulation | IEC62109-1, IEC62109-2 | ||
EMC | EN61000-6-1, EN61000-6-3 | ||
General Data | |||
Operating Temperature Range (ºC) | -25~60ºC, >45ºC Derating | ||
Cooling | Smart cooling | ||
Noise (dB) | <30 dB | ||
Communication with BMS | RS485; CAN | ||
Weight (kg) | 20.5 | ||
Size (mm) | 330W×580H×232D | ||
Protection Degree | IP65 | ||
Installation Style | Wall-mounted | ||
Warranty | 5 years |
Payment Term | T/T | EXW | 30% T/T in advance, paid the balance before shipment |
FOB | |||
CFR(C&F) | 30% T/T in advance, paid the balance against copy of B/L | ||
CIF | |||
L/C | L/C amount above 50,00 USD, we can accept L/C at sight | ||
West Union | Amount lower than 5000USD | ||
Delivery Time | 7~10days after receiving payment for one container |