Features of BDM300
* Qualified equipment that meets Hawaiian Electric TroV-2 and full frequency and voltage ride-through
* Cable options including conventional trunk cable and daisy chain
*Thinnest micro inverter in world, 25mm in thickness
* Designed for frame mount (AC module), as well as rail mount solutions * High continuous output power up to 300Wac, recommended for max 380W solar panels
* High efficiency with 95.5% CEC * Globally certified for c-ETL-us, SAA, TUV, VDE-AR-N 4105, VDE 0126, G83/2,CEI 021,IEC61727,EN50438
* Integrated grounding for easy installation & NEMA-6/IP-66/IP-67 enclosure rating
* Integrated monitoring and power line communication with BDG-256 gateway
INPUT(DC) | Recommended Max PV Power (Wp) | 380 | ||
Max DC Open Circuit Voltage (Vdc) | 60 | |||
Max DC Input Current (Adc) | 12 | |||
MPPT Tracking Accuracy | >99.5% | |||
MPPT Tracking Range (Vdc) | 22-55 | |||
Isc PV (absolute maximum) (Adc) | 14 | |||
Maximum Inverter Backfeed Current to the Array (Adc) | 0 | |||
OUTPUT(AC) | Peak AC Output Power (Wp) | 250(continuous) | ||
Nominal Power Grid Voltage (Vac) | 240 | 208 | 230 | |
Allowable Power Grid Voltage (Vac) | 211-264 | 183-229 | configurable | |
Allowable Power Grid Frequency (Hz) | 59.3 a 60.5 | |||
THD | <3% (at rated power) | |||
Power Factor (cos phi, fixed) | >0.99 (at rated power) | |||
Rated Output Current (Aac) | 1.04 | 1.20 | 1.09 | |
Current (inrush)(Peak and Duration) | 24A, 15us | |||
Nominal Frequency (Hz) | 60 | 50 | ||
Maximum Output Fault Current (Aac) | 2.2A peak | |||
Maximum Output Overcurrent Protection (Aac) | 6.3 | |||
Maximum Number of Units Per Branch (20A) (All NEC adjustment factors have been considered) | 13 | |||
SYSTEM EFFICIENCY | Weighted Averaged Efficiency (CEC) | 95.50% | ||
Night Time Tare Loss (Wp) | 0.08/0.06/0.07 | |||
PROTECTION FUNCTIONS | Over/Under Voltage Protection | Yes | ||
Over/Under Frequency Protection | Yes | |||
Anti-Islanding Protection | Yes | |||
Over Current Protection | Yes | |||
Reverse DC Polarity Protection | Yes | |||
Overload Protection | Yes | |||
Protection Degree | NEMA-6/IP66/IP67 | |||
Ambient Temperature | -40°C to +65°C | |||
Operating Temperature | -40°C to +85°C | |||
Display | LED LIGHT | |||
Comunications | Power Line | |||
Dimension (W-H-D) | 230x138x35 mm | |||
Weight | 4.6 Ibs. (2.1 kg) | |||
Environment Category | Indoor and outdoor | |||
Wet Location | Suitable | |||
Pollution Degree | PD3 | |||
Overvoltage Category | II(PV), III (AC MAINS) | |||
Product Safety Compliance | 1741 NOM C22.2 No. 107.1 | |||
Grid Code Compliance* (Refer to the label for the detailed grid code compliance) | ΙΕΕE 1547 |
1.Do you offer OEM/ODM service?