Product Details | |
Model Number | CBB61 with terminals, CBB61 with wires |
Type | Polyester Film Capacitor, Polypropylene film capacitor |
Place of Origin | Guangdong, China |
Brand Name | SMILER |
Supplier Type | Original manufacturer, ODM |
Capacitance | 0.1uf~100uf |
Cross Reference | CBB61 cable type, CBB61 capacitor |
Media Available | datasheet, Photo |
Tolerance | +_5%(J),+_10%(K) |
Package Type | plastic |
Rated Voltage | 100VAC~630VAC(50-60Hz) |
Operating Temperature | -40°--85° |
Brand | CBB61 |
Specification | wires or terminals type |
Voltage - Rated | 100VAC~630VAC(50-60Hz) |
ESR (Equivalent Series Resistance) | 4000(mΩ) |
Applications | motor, fan, air conditioner etc. |
Impedance | 4000(mΩ) |
Circuit Type | Bussed |
Current - Leakage | CBB61-S3 |
Voltage - Breakdown | Not Applicable |
Capacitance Range | 0-100uf |
Application | motor, fan, air conditioner etc. |
Safety approvals | CQC/U-L/VDE/TUV/CE |
Approval standard | GB/T3667,U-L810,EN60252-1 |
Climatic category | 25/70/21,25/85/21 |
Rated voltage | 250VAC~500VAC(50-60Hz) |
Capacitance tolerance | +_5%(J),+_10%(K) |
Between terminals | 2*Un(VAC)/3s(CQC,VDE,TUV),1.5*Un(VAC)/3s(U/L) |
Insulation Resistance(20) | between terminals and case>=5000/C(100VDC,3s) |
|
|
|
|
|
|
Capacitance(uf) | 250V | 300V | 400V | 450V | 500V |
| L/W/H | L/W/H | L/W/H | L/W/H | L/W/H |
0.8UF | 32*10*20 | 32*10*20 | 32*10*20 | 32*11*22 | 36*11*22 |
1.0UF | 32*10*20 | 32*11*22 | 32*11*22 | 36*10*20 | 36*13*23 |
1.2UF | 32*10*20 | 32*11*22 | 36*10*20 | 36*11*22 | 37*13*24 |
1.5UF | 36*10*20 | 36*11*22 | 36*11*22 | 37*13*24 | 37*15*27 |
2.5UF | 36*10*20 | 36*13*23 | 36*13*23 | 38*15*25 | 38*17*28 |
3.0UF | 36*11*22 | 37*13*24 | 38*15*25 | 38*17*28 | 38*19*31 |
3.5UF | 36*11*22 | 38*15*25 | 38*17*28 | 38*18*29 | 47*19*31 |
4.0UF | 36*13*23 | 37*15*27 | 38*17*28 | 38*19*31 | 47*19*33 |
5.0UF | 37*13*24 | 38*17*28 | 47*17*28 | 47*19*33 | 47*25*35 |
6.0UF | 38*15*25 | 38*18*29 | 48*19*31 | 47*20*35 | 47*27*37 |
8.0UF | 38*17*28 | 47*17*31 | 47*20*35 | 47*25*35 | 47*30*43 |
Fan capacitors use high-pressure and high-temperature resistant materials. They are small in shape and flexible in installation. The lead-out can also be changed according to different application scenarios. With high safety and long service life, we can design dimensions and standards according to customer's use and installation requirements
CBB61 starting capacitor is a kind of machine which is suitable for starting and running of single-phase motor with 50HZ AC power supply, and also can speed control the motor. It is an important supporting part of electric fan, range hood, air conditioning fan, toaster and so on.
How to determine the good or bad fan capacitor
Fan capacitors are prone to failure, making them unusable. So how to determine the good or bad fan capacitor? Let's take a look at the relevant knowledge right away.
How to judge the good and bad of fan capacitor
Measure with pointer multimeter
Rotate the switch to the K-file range, use the meter needle to contact the positive and negative poles of the capacitor to see if the capacitor has the phenomenon of discharge.
If the meter needle swings up to the right and returns to the left, it proves that the capacitor accident is good; if the meter needle swings up and slowly returns to a certain position and stops, it proves that the capacitor is leaking and should be repaired in time.
Measure with digital capacitance meter
Compared with the pointer multimeter, this operation is simpler to check, firstly, the positive and negative meter needles of the capacitor meter will touch the positive and negative poles of the capacitor respectively. If the value is close to or equal to the nominal capacity of the capacitor case, it proves that the capacitor is not broken and can be used; if the value is obviously lower than the nominal capacity of the capacitor case, it proves that the capacitor is damaged and should be replaced with a new one in time.
Short connect with two wires
Connect the measuring not short circuit capacitor to 220V hole, let the capacitor charge first, short the two wires on the capacitor, if you hear the sound of snapping and electric spark appears, it proves the capacitor is good. If no spark appears that proves the capacitor has been damaged.
Precautions when using Fans
Reasons for installing a starting capacitor in an electric fan.
It is necessary to install a capacitor in the electric fan. The single-phase voltage of 220 volts itself (phase voltage) has no phase angle, while the household fan motor consists of a main winding and a secondary winding (auxiliary winding).
If the secondary winding is connected in series with a capacitor to reach the angle of the secondary winding electromagnetic field beyond the main winding, thus generating an angled pulling field in the motor rotor to rotate the rotor, only the three-phase power supply (line voltage) has a phase angle of 60 degrees between phases, so the three-phase AC motor does not need a starting capacitor.
How large is the capacitance of an electric fan?
The capacitance of an electric fan is typically 1 to 2 microfarads, mostly 1.2 microfarads. Generally speaking, a capacitor induction motor contains 2 windings, the start winding and the run winding, which are 90° apart in space.
Of course, the capacitance size is related to the fan size, for example: 16": 1.5μ, 12 to 14": 1.2μ, 8 to 10": 1μ, ceiling fan: 2.2 to 2.5μ, table fan: 1.2 to 1.5μ, and turntable fan: 1.0 to 1.2μ.