Dw-Gc1120 Laboratory Equipment Chromatography Fid Tcd Fpd Npd Gas Chromatography Instrument

Min.Order: 1
Product origin: Chongqing, China
Infringement complaint: complaintComplaint
US$ 3355 ~ 9999

Description
Product Description
   Gas Chromatography 
 
Model# DW-GC1120
Sample Introduction Systemsample injector and evaporation chamber
Column OvenTemperature rangeAmbient temperature +7ºC ~ 400ºC  (in 1ºC increment)
Temperature accuracy ± 0.02ºC
Cooling time400ºC to 50ºC in 8-10 min at 25ºC ambient
Programmed temperature setting0.1ºC~40ºC/min (in 1ºC increment)
Program ramps7 ramps in total (10 ramps available with control workstation)
Size (L*W*H)284*280*241mm(inside)340*345*281mm(outside)
Flame Ionization Detector
(FID)
Detection limit3×10-12g/s (C16
Best test result3×10-12g/s (C16)
Drift6×10-13A/30min
Noise5×10-14A
Linearity range106
Thermal Conductivity Detector
(TCD)
Sensitivity≥5000mV, mL/mg (C16)
Baseline noise20µV
Drift60µV/h
Linearity range104
Flame Photometric Detector
(FPD)
Detection limit8×10-13g/s(P) ; 8×10-11g/s(S)
Drift2×10-11A/30min
Baseline noise5×10-12A
Nitrogen-Phosphorus Detector
(NPD)
Detection limit≤5×10-12g/s(N)  (Azobenzene)
          ≤5×10-13g/s(P)  (Malathion)
Features:   
Control system: designed for monitoring and controlling the instrument via the computer.
Column Compartment/oven with superior thermal performance, multistage (10 ramps) programmed temperature control function. (supported by "control system")
Advanced built-in data acquisition system , supporting real time instrument status monitoring, detection signal acquisition and PC control
Column oven accommodates up to 3 chromatographic columns, and supports quick heat-up and rapid cool-down with automated back-door opening.
Flexible sample introduction system: 3 sample injectors could be installed and operated simultaneously with independent temperature control.
High sensibility and stability detector.
2 independent and analog signals output.
M6 software, compatible with GLP/FDA-21 CFR Part11 requirements and regulations. (electronic records and signatures)
Gas chromatography and accessories:   
Carrier Gas System + Sample Introduction System + Separation System + Temperature Control System + Detector
Carrier Gas System: air source/ purification and desiccation device/ flow rate control device
Sample Introduction System: sample injector
Separation System: chromatographic column(packed column and capillary column)
Temperature Control System (Column Oven): constant temperature and programmed temperature
Detector: FID/ TCD/ FPD/ NPD
    
Advanced Microcomputer Control System   
Superior performance with advanced, microcomputer-based temperature control system
High temperature accuracy (optimum ± 0.02ºC), high reliability, and anti-interference
Self-diagnosis/ self-protection function (overheat protection, power-off protection, etc.)
Intuitive display of timing program, detector status, measurement range, current setting, etc

 