Environmental Chambers (Liquid nitrogen)

Min.Order: 1
Product origin: Beijing, China
Infringement complaint: complaintComplaint
US$ 8000 ~ 13000

Description

Liquid nitrogen type high-low temperature chambers are used for tensile, compression, bending, fatigue and other mechanical properties tests for rubber, plastic and other non-metallic materials, metal materials and composite materials in high and low temperature environment. They can be used with electronic universal testing machines and electro-hydraulic servo universal testing machines.

 

These high and low temperature environmental chambers can meet the technical requirements of ISO or ASTM standard if any.

 

1. The door is in front of the chamber with stainless steel. The chamber is equipped with an observation window, and there is lighting in the chamber to facilitate the observation in the test process.

2. The chamber adopts liquid nitrogen jet refrigeration at low temperature; According to the test temperature heat compensation, heating is performed by resistance wires or hi-temp superalloy tubes.

3. It can perform tensile, compression, bending and other tests, and can measure tensile compression deformation, bending deflection and other parameters. The fixtures can be placed in the environmental chamber during the environmental test.

4. The deformation measuring device can choose different sensors according to the different temperature ranges, such as bilateral extraction structure or direct measurement in the chamber.

5. The supporting cart is of frame structure, and the linear guide rail structure is applied to ensure the smooth sliding of the chamber. The front track of the supporting cart extends into the space of testing machine, and the chamber body is placed on the track of the cart. When the chamber is not used for a long time, cart can also be moved to any place as a whole. The supporting cart is equipped with casters at the bottom, easy to move.

6. There is an air circulation system in the chamber to ensure that the temperature gradient and fluctuation can meet the relevant standards. The safety device has over-temperature, overload, over-current, phase sequence protection and circuit breaker protection functions.

7. Working temperature range:-190ºC~+400ºC(-190ºC~+500ºC available).

 

Specifications and parameters :

Power

AC   380V  3.5kVA   50Hz

Rated Current

10A

Starting Current

11A

Control Mode

PID

Cooling Method

Liquid nitrogen

Ambient Temperature

+5ºC~+35ºC

Performance

Chamber Temperature Range

-190ºC~+400ºC

Temperature Deviation

  ±3ºC

Cooling Time

Around 20 mins: +20ºC to -190ºC

Heating Time

Around 40 mins:+20ºC to 400ºC

Composition

Materials

Outer housing

Cold-rolled steel plate spraying treatment

Inner housing

1Cr18Ni9Ti Stainless steel plate

Thermal insulation layer

Aluminum silicate cotton

Chamber

Temperature regulator

Heater, blower, nozzle

Testing room

Thermocouple, lighting

Upper and lower openings

Φ50.(Adjustable)

Control cabinet

Automatic digital display temperature regulator, power   cord, switchboard, etc

Cart

Movable cart, height adjustable.

Heating system

Resistance wire/superalloy heating tube

Cooling system

LN2 Low temperature valve

Blower

Propeller type centrifugal blower

Safety devices

Short circuit protector, phase sequence protector, fuse,   overtemperature alarm

Size

Inner: L*W*H (mm)

Customized according to test requirements

Outer: L*W*H (mm)

Customized according to test requirements

Working with MTS E45 tensile machine.