Test stand rotation (rpm) | 1 to 3 adjustable |
Turntable diameter(mm) | 400 |
Pendulum radius(mm) | 400 |
Load KG | 10KG |
Radius of water spray ring | 400mm |
Spray pipe swing angle range | 120°320°(can be set) |
Diameter of water spray hole (mm) | φ0.4 |
Flow rate of each water spray hole | 0.07 L/min +5% |
Water spray pressure (Kpa) | 80-150 |
Pendulum tube swing | max ±160° |
Swing speed of water jet pipe | IP3 15 times/min; IP4 5 times/min |
Distance between test sample and test equipment | 200mm |
Water source and consumption | pure water or distilled water 8 litres/day |
Controller | self-developed PLC touch screen controller |
Spraying system | 18 nozzles |
Electrical controller | LCD display touch key controller |
Test time | 999S adjustable |
Speed control | using frequency conversion governor or stepper motor, smooth speed regulation, high control accuracy |
Manometer | dial type manometer to display the pressure of each single column test level |
Flow meter | digital water flow measurement, showing the flow rate of each single column test level |
Flow and pressure control | Flow and pressure control by manual valve. Digital flow meter indicating flow rate. Stainless steel case spring loaded pressure gauge indicating pressure |
Preset test time | 0s to 99H59M59S adjustable |
Ambient temperature | RT~50ºC(average temperature in 24H≤28ºC) |
Ambient humidity | ≤85%RH |
Power supply | 1. AC220V three-phase four-wire + protection ground,. Grounding resistance of the protective earth line is less than 4Ω. 2. The user is required to configure an air or power switch of appropriate capacity for the equipment at the installation site, and this switch must be independent and dedicated to the equipment. |
Power | approx. 6KW |
Outer box material | SUS202# stainless steel plate or cold tie plate spray plastic |
Protection system | leakage, short circuit, water shortage, motor overheating protection |