project | S6520X-30QC-EI | S6520X-30HC-EI | S6520X-54QC-EI | S6520X-54HC-EI | S6520X-30HF-EI | S6520X-54HF-EI | |
exchange capacity | 2.56Tbps/25.6Tbps | ||||||
packet forwarding rate | 720Mpps/1260Mpps | 1260Mpps | 1080Mpps/1620Mpps | 1620Mpps | 1260Mpps | 1620Mpps | |
Full weight | ≤7kg | ≤7.4kg | ≤7.2kg | ≤7.6kg | ≤5.5kg | ≤6.0kg | |
Dimensions (W×D×H) (unit: mm) | 440×360×43.6 | ||||||
Console port | 1 | ||||||
Ethernet port for management | 1 | ||||||
USB port | 1 | ||||||
SFP+ | twenty four | twenty four | 48 | 48 | twenty four | 48 | |
QSFP+ | 2 | - | 2 | - | - | - | |
QSFP28 | - | 2 | - | 2 | 6 | 6 | |
Expansion slot | 2 | N/A | |||||
Expansion board | 8-Port 10 Gigabit SFP+ Optical Interface Board | ||||||
2-port 40GE QSFP+ optical interface card | |||||||
2-port 25GE SFP28 interface card | |||||||
8-port 10G/5G/2.5G/1GBase-T interface card | |||||||
8-port 5G/2.5G/1GBase-T interface card | |||||||
2-port 100GE QSFP28 optical interface board | 2-port 100GE QSFP28 optical interface board | ||||||
8-port 25GE SFP28 optical interface board | 8-port 25GE SFP28 optical interface board | ||||||
Netstream card | |||||||
mini-iMC card | |||||||
Eagle Vision Scanner Card | |||||||
Firewall card | |||||||
Input voltage | comminicate | Rated voltage range: 100V~240V AC, 50/60Hz | |||||
Maximum voltage range: 90V~264V AC, 47/63Hz | |||||||
DC | Rated input voltage range: -48V~-60V DC | ||||||
Maximum input voltage range: -36V~-72V DC | |||||||
power module | Dual Modular Power Supplies | ||||||
fan module | Dual modular fans, front-to-rear or rear-to-front ventilation | Three modular fans, front-to-rear or rear-to-front ventilation | |||||
Power consumption (W) | MIN: Single AC: 38W Dual AC: 43W | MIN: Single AC: 38W Dual AC: 43W | MIN: Single AC: 39W Dual AC: 44W | MIN: Single AC: 44W Dual AC: 49W | MIN: Single AC: 29W Dual AC: 35W | MIN: Single AC: 29W Dual AC: 36W | |
MAX: Single AC: 179W Dual AC: 183W | MAX: Single AC: 197W Dual AC: 200W | MAX: Single AC: 231W Dual AC: 234W | MAX: Single AC: 249W Dual AC: 251W | MAX: Single AC: 131W Dual AC: 134W | MAX: Single AC: 163W Dual AC: 162W | ||
Working temperature | -5ºC~45ºC | ||||||
Relative humidity of working environment (non-condensing) | 5%~95% |
Horizontal virtualization | Support IRF2 Intelligent Resilience Architecture |
Support distributed device management, distributed link aggregation, distributed elastic routing | |
Supports stacking via standard Ethernet interface | |
Supports local stacking and remote stacking | |
Support MAD stack split detection mechanism based on LACP, BFD and ARP | |
Stack up to 9 units | |
link aggregation | Support 10GE port aggregation |
Support 40GE port aggregation | |
Support static aggregation, dynamic aggregation | |
Jumbo Frame | support |
MAC address table | Support static MAC address |
Support black hole MAC address | |
Supports setting the maximum number of port MAC addresses to learn | |
SDN/Openflow | Support OpenFlow 1.3 standard Support multi-controller (EQUAL mode, active/standby mode) Support multi-table pipeline Support Group table Meter support |
VLAN | Supports port-based VLANs (4094) |
Support Default VLAN | |
Support QINQ | |
Support flexible QINQ | |
Support VLAN MAPPING | |
Support PVST+ Support RPVST+ | |
Support VLAN division based on IP and MAC | |
data monitoring | Support SFLOW, NetStream* |
MPLS | MPLS support Support MCE Support MPLS VPN, VPLS Support MPLS TE* |
DHCP | DHCP Client |
DHCP Snooping | |
DHCP Relay | |
DHCP Server | |
DHCP Snooping option82/DHCP Relay option82 | |
ARP | Support static entries |
Support gratuitous ARP | |
Supports standard proxy ARP and local proxy ARP | |
Support Dynamic ARP Inspection (DAI) | |
Support ARP anti-attack | |
Support ARP source suppression | |
Support ARP Detection function (can check according to DHCP Snooping security entry, 802.1x entry, or IP/MAC static binding entry) | |
Routing Protocol | Support IPv4/IPv6 static routing, support dual stack |
Support RIPv1/v2, RIPng | |
Support OSPFv1/v2, OSPFv3 | |
Support BGP4, BGP4+ for IPv6 | |
Support IS-IS, IS-IS V6 | |
Support equal-cost routing, policy routing | |
Support VRRP/VRRPv3 | |
IPv6 Features | Support ND (Neighbor Discovery) |
Support PMTU | |
Supports ICMP v6, Telnet v6, SFTP v6, SNMP v6, BFD v6, VRRP v3, IS-ISv6, BGP4+ for IPv6 | |
Support IPv6 Portal | |
Support IPv6 tunnel | |
VxLAN | Support VXLAN Layer 2 switching |
Support VXLAN routing switching | |
Support VXLAN centralized gateway, distributed Anycast gateway | |
Support BGP EVPN | |
VxLAN centralized control plane and automated deployment supporting OpenFlow+Netconf | |
Data Center Features | Support PFC, ECN |
multicast protocol | Support IGMP Snooping v2/v3 |
Support IGMP Snooping Fast-leave | |
Support IGMP Snooping Group-policy | |
Support PIM-SM, PIM-DM, PIM-SSM | |
Support PIM snooping | |
MVRP support | |
Support MFF | |
Support Enhanced Layer 3 Multicast Protocol | |
Zero configuration | Supports zero configuration methods such as DHCP auto-config and CWMP-TR069 |
Broadcast/Multicast/Unicast Storm Suppression | Supports storm suppression based on port rate percentage |
Support pps-based storm suppression | |
Support bps-based storm suppression | |
Layer 2 Ring Network Protocol | Support STP/RSTP/MSTP protocol |
Support STP Root Guard | |
Support BPDU Guard | |
Support ERPS Ethernet ring protection protocol (G.8032) | |
QoS/ACL | Supports limiting the rate at which the port receives packets and the rate at which it sends packets |
Support CAR function | |
Each port supports 8 output queues | |
Support flexible queue scheduling algorithm, can be set based on port and queue at the same time, support SP, WDRR, WRR, WFQ, SP+WDRR and other modes | |
Supports 802.1p and DSCP priority re-marking of packets | |
Support L2 (Layer 2) ~ L4 (Layer 4) packet filtering function, provide based on source MAC address, destination MAC address, source IP (IPv4/IPv6) address, destination IP (IPv4/IPv6) address, port, protocol, VLAN flow classification | |
Support Time Range (Time Range) | |
WRED support | |
mirror | Stream mirroring supported |
Support N:4 port mirroring | |
Supports local and remote port mirroring | |
Support ERSPAN | |
safety features | Support user hierarchical management and password protection |
Support centralized MAC authentication | |
802.1X support | |
Support storm constraints | |
Support AAA authentication | |
Support Portal authentication | |
Support RADIUS authentication | |
Support HWTACACS | |
SSH 2.0 support | |
Support port isolation | |
Support port security | |
Support EAD | |
Support SAVI and SAVA to ensure the security of IPv6 environment | |
Can support DHCP Snooping, DHCPv6 Snooping, prevent spoofed DHCP server | |
Support Dynamic ARP Inspection (DAI) to prevent man-in-the-middle attacks and ARP denial of service | |
Support anti-DOS attack | |
Support anti-ARP attack | |
Support anti-ICMP attack | |
Support CPU protection | |
Support BPDU guard, Root guard | |
Support IP+MAC+Port binding | |
Support IP Source Guard | |
Support HTTPs | |
SSL support | |
Support PKI (Public Key Infrastructure, public key infrastructure) | |
Support CPU anti-attack | |
Load and upgrade | Support XModem protocol to achieve loading upgrade |
Support FTP (File Transfer Protocol) loading and upgrading | |
Support TFTP (Trivial File Transfer Protocol) loading and upgrading | |
management and maintenance | Supports Command Line Interface (CLI) configuration |
Support Telnet remote configuration | |
Support configuration through Console port | |
Support schedule job | |
ISSU support | |
Support 802.1AG and 802.3AH | |
Support SNMP (Simple Network Management Protocol) | |
Support NetStream function, traffic analysis sampling ratio 1:1 | |
Support IMC network management system | |
Support Telemetry visualization | |
Support NETCONF network management protocol | |
Support Python script management operation and maintenance | |
Support system log Syslog | |
Supports graded alarms | |
Support NTP, PTP | |
Support power alarm function | |
Support fan, temperature alarm | |
Support debug information output | |
Support Ping, Tracert | |
Track support | |
Support Telnet remote maintenance | |
Support USB for file upload and download, support for USB deployment |
We focus on the IDC data center field, have professional enterprise-level products, and provide complete planning and design solutions.
Main Application Scenarios:
SDS, VDI, CDN, virtualization, big data, database, cloud scenarios, AI inference, small businesses, OA, and web application.
Delivery time : 15-45 working days after payment receipt confirmed (based on actual quantity). |
Original packaging to ensure product quality and safety. |
Professional goods shipping forwarder. |
We guarantee that all products are original and authentic. All support after-sales inspection. Regarding xFusion server, we can provide remote technical services and troubleshooting. In addition to new retail products. Others have used NEW BULK. We provide a complete test report. Please rest assured to buy. The stock is huge. Many products are not released in time. If you need more product quotations. You can email to contact us at any time. | ||||
Q1: How can I believe that your product is of good quality?
A1: We guarantee that all products are original products.We provide a complete test report.
Q2: When can I get a quote?
A2: We will usually quote you within 24 hours after receiving your inquiry. If you really want to get a quotation and more other questions, you can contact us via trademessage or email.
Q3: Why choose you?
Q3: As an Audited Supplier,we have a good reputation on our customers,because of the good quality,suitable price and good service.
Q4: What is your payment?
A4: T/T wire bank transfer.