Outdoor UPS 1kVA to 10kVA High Frequency Online UPS Uninterrupted Power Supply

Min.Order: 5
Product origin: Shenzhen, Guangdong, China
Infringement complaint: complaintComplaint
US$ 699

Description

Outdoor UPS 1kVA to 10kVA High Frequency Online UPS Uninterrupted Power Supply




Key features

1.ZLPOWER Outdoor Intelligent High Frequency Online UPS provide continuous pure sine wave AC power supply for
outside communications / network equipment.

2.Double-conversion online design, high temperature resistant, anti-cold, sealing level for IP65; With the wide range of input voltage and frequency of input window (- 45% +35% rated voltage and ± 10% rated frequency), in many remote areas of China after a severe test of the grid.

3.Using microprocessor control, directly produce highfrequency pulse width modulation wave (SPWM) control of the UPS inverter, to simplify the UPS control circuit, to improve the stability, to have more real-time UPS to quickly respond to changes in the external environment and guarantee the machine's control circuit is more simple and reliable.

4.Using digital control techniques, to avoid the traditional analog control temperature drift inherent defects such as hardware parameters, to ensure consistency and reliability of UPS.

Specification:
 
ModelRA1KLRA2KLRA3KLRA6KLRA10KL
CapacityVA/W1000VA/800W2000VA/1600W3000VA/2400W6000VA/4800W10000VA/8000W
InputNominal Voltage200/208/220/230/240VAC
Voltage Range115~300VAC125~275VAC
Power Factor0.97
Frequency Range50Hz:46~54Hz; 60Hz:56~64Hz
OutputVoltage200/208/220/230/240(1±2%)VAC200/208/220/230/240(1±1%)VAC
Frequency50/60Hz (Adjustable);
50Hz AC Mode: Follow AC Mode (AC Range 46~54Hz); Battery Mode: 50Hz (1±0.2%)                                                                                                60Hz AC Mode: Follow AC Mode (AC Range 56~64Hz); Battery Mode: 60Hz (1±0.2%)
Wave FormPure sine wave
Power Factor0.8
Harmonic Distortion3% THD (Linear load)
7% THD (Non-Linear load)
2% THD (Linear load)

6% THD (Non-Linear load)
Overload Capacity110%~150%  maintain 30s then turn to bypass ourput;
>150% maintain 300ms
Load <105% work consistant;
105%
<load <125% 1min;
125%
<load <135% 30sec;>135% 0.5sec
Current Crest Ratio3:01
ConnectionsTerminal block
EfficiencyBattery Mode83%87%
AC Mode85%88%
BatteryTypeSealed free maintenance lead acid battery
Nominal DC voltage36VDC96VDC96VDC192VDC192VDC
Stansard Battery Cabinet3*100AH8*100AH8*100AH16*38AH16*38AH
Backup Time (Full Load)Depens on the capacity of internal battery bank(24AH,38AH,65AH,80AH and 100AH optional)Depens on the capacity of internal battery bank(24AH,38AH optional)
Charge Current (Max)6.0A6.0A6.0A2.0A2.0A
Charge Voltage (VDC)41.1V±0.2VDC110V±0.6VDC110V±0.6VDC219.5V±1.1%VDC219.5V±1.1%VDC
Recharge TimeDepends on the capacity of  internal battery bank
BypassAutomatic TransferOn overload and UPS failure
Before UPS Power-onYES
Transfer Time 0 ms(from imain to battery and vice versa); Less than 4ms from inverter to bypass and vice versa
indicatorsLCD DisplayUPS status, Battery capacity, loading, Fault code (LCD: I/P &O/P voltage&frequency, Battery voltage)
Audible Bypass, Battery mode, Battery low, Overload, Fault
CommunicationsIntelligent RS232 serial portSoftware support Windows family software, Linux, Sun network operating system, IBM Aix, Compaq True64 SGI IRIX, FreeBSD, HP-UX and MAC 
SNMP (Optional)Remote control UPS through SNMP management and Internet
USB (Optional)Windows family software and Mac OS
EnvironmentalOperating Temperature0~40ºC
Operating Humidity0~95% (No condensing)
UPS dimensionL*W*H (mm)(UPS main body)482*380*88.4482*448*88.4482*448*88.4632*482*133.4632*482*133.4
L*W*H (mm)(Cabinet)638*507*775612*525*1511612*525*1511718*595*1371718*595*1371
Weight(kg)Net Weight (No battery)52.00100.00100.00120.00123.00

Company show:



https://zlpower.en.made-in-china.com/contact-info.html
Product Tag:
Related categories:
Scroll to Top