8-10kw R32 Residentail Inverter Split Heat Pump Water Heater

Min.Order: 20
Product origin: Foshan, Guangdong, China
Infringement complaint: complaintComplaint
US$ 900 ~ 3500

Description
8-10kw R32 Residentail Inverter Split Heat Pump Water Heater 

Features:

1.Hot water up to 65ºC,suitable for underfloor/radiator heating/fan coil

2.With EVI system,can work stable at ambient temperature -25ºC to 45ºC

3.E-Heater,diverter valve and water pump can be inclueded

4. A+++ Energy Rating Level

5.Full inverter system,Stable and efficient performance.

6.R32 System,environment friendly

7.Application Scope:Hotels,clubs,hospitals,villas and any place in need of air conditioning,heating and hot water

8.With Wifi App control


 

 
Market model WW08V-SWW10V-SWW12V-SWW14VM-S
Heating1Output CapacitykW3.40~8.653.70~10.304.95~12.465.92~14.94
Input Power kW0.59~1.650.62~2.050.90~2.481.15~3.20
COP-5.23~5.725.02~5.905.03~5.504.67~5.12
Input CurrentA2.82~7.922.96~9.814.31~11.855.50~15.3
Heating2Output CapacitykW3.43~7.773.90~9.844.37~12.435.18~14.30
Input Power kW0.91~2.411.01~3.121.21~3.951.33~4.69
COP-3.23~3.803.15~3.813.15~3.613.05~3.89
Input CurrentA2.56~11.524.83~14.935.78~18.896.36~22.45
Heating3Output CapacitykW4.11~10.375.10~13.256.25~14.637.52~16.57
Input Power kW0.74~2.280.94~13.731.14~3.121.37~3.56
COP-4.55~5.564.61~5.424.69~5.464.66~5.47
Input CurrentA3.54~10.914.50~12.495.45~14.936.55~17.03
Cooling4Output CapacitykW3.04~7.573.82~8.215.05~11.456.02~12.31
Input Power kW0.94~2.751.18~3.021.54~4.131.87~4.53
EER-2.75~3.232.72~3.252.77~3.282.73~3.22
Input CurrentA4.50~13.155.64~14.457.37~19.768.95~21.67
Power Supply V/PH/HZ220-240V/1/50Hz
ErP level(35ºC)-A+++A+++A+++A+++
ErP level(55ºC)-A++A++A++A++
Water Side Heat Exchanger -Plate heat exchanger
Display controller -LCD touch screen
Backup heater (Optional) kW3kW 
Expansion vessel-5L
Refrigerant Type -R32
Max Water Temperature
 (without backup heater)
ºC60
Working Ambeint TemperatureºC-25~43
Water connection inchG1-1/4
Sound pressure Level @1m outdoor unitdB(A)50505253
indoor unitdB(A)27272727
Net Dimension (L*W*H) outdoor unitmm995*410*800995*410*8001065*410*9601065*410*960
indoor unitmm475*220*800475*220*800475*220*800475*220*800
 
Market model WW14VT-SWW16V-SWW18V-SWW20V-SWW22V-S
Heating1Output CapacitykW5.92~14.946.48~16.387.29~18.518.10~20.568.91~22.35
Input Power kW1.15~3.201.29~3.581.39~3.981.56~4.491.73~5.06
COP-4.67~5.124.57~5.014.65~5.254.58~5.204.42~5.13
Input CurrentA2.05~5.712.31~6.412.49~7.122.79~8.033.09~9.06
Heating2Output CapacitykW5.18~14.305.93~16.586.67~18.657.41~20.688.15~21.15
Input Power kW1.33~4.691.39~5.631.58~6.431.77~7.181.97~7.50
COP-3.05~3.892.94~4.262.90~4.222.88~4.182.82~4.13
Input CurrentA2.38~8.392.48~10.072.83~11.503.17~12.843.52~13.42
Heating3Output CapacitykW7.52~16.578.95~19.4210.07~21.8511.18~24.0512.30~25.5
Input Power kW1.37~3.561.62~4.211.84~4.772.08~5.312.33~5.73
COP-4.66~5.474.61~5.524.58~5.464.53~5.384.45~5.28
Input CurrentA2.45~6.372.90~7.533.29~8.533.72~9.504.17~10.25
Cooling4Output CapacitykW6.02~12.317.23~14.828.13~15.729.03~16.679.93~17.50
Input Power kW1.87~4.532.27~5.432.64~5.863.00~6.363.35~6.78
EER-2.73~3.222.73~3.182.68~3.082.62~3.012.58~2.96
Input CurrentA3.34~8.104.06~9.714.72~10.485.37~11.386.00~12.13
Power Supply V/PH/HZ380-415V/3/50Hz
ErP level(35ºC)-A+++A+++A+++A+++A+++
ErP level(55ºC)-A++A++A++A++A++
Water Side Heat Exchanger -Plate heat exchanger
Display controller -LCD touch screen
Backup heater (Optional) kW3kW 
Expansion vessel-5L
Refrigerant Type -R32
Max Water Temperature
(without backup heater)
ºC60
Working Ambeint TemperatureºC-25~43
Water connection inchG1-1/4
Sound pressure Level @1m outdoor unitdB(A)5356565858
indoor unitdB(A)2727272727
Net Dimension (L*W*H) outdoor unitmm1065*410*9601065*410*9601150*430*13501150*430*13501150*430*1350
indoor unitmm475*220*800475*220*800475*220*800475*220*800475*220*800

Note:
1.Outdoor air temperature 7ºC DB,6ºC WB;EWT 30ºC,LWT 35ºC.
2.Outdoor air temperature 7ºC DB,6ºC WB;EWT 47ºC,LWT 55ºC.
3.Outdoor air temperature 20ºC DB,15ºC WB;EWT 15ºC,LWT 55ºC.
4.Outdoor air temperature 35ºC DB,24ºC WB;EWT 12ºC,LWT 7ºC.
5.The Specifications are subject to changes without notice.


R32 environmental refrigerant

1. R32 has a GWP of 675, roughly 30% lower than that of R410A
2. R32 systems use up to 20% less refrigerant than R410A, making them more efficient and cost less to operate
3. Ozone Depletion Potential of 0
4. Easier to recycle than R410A, as R32 is a single component refrigerant

DHW tank disinfection

The DHW tank disinfection function is used to kill legionella by 65°C water to ensure the health and safety.


Climate curve
You can choose different climate correlation curves or your own customised curve. Once the curve is selected, the unit sets the outlet water temperature automatically according to the outdoor ambient air temperature.

Floor preheating and drying

Protect your home floor by activating the Floor Preheating function which slowly increases the heating temperature of the floor coils, avoiding possible floor damaging and transitioning smoothly to the heating function. The Floor Drying Up function provides an additional solution to the installer as it helps remove any residual moisture from newly installed floor coils, further protecting the installation and ensuring the optimal and effective operation of the heat pump.

Powerful heating with high efficiency

1. No capacity attenuation at -l0°C ambient temperature
2. Operation range down to -25°C
3. Maximum LWT reach 60°C 
4. Energy efficiency level: A+++
 

 

Mode combination

There are 4 single operation mode (Cool,Heat,DHW,Auto) and 3 combined operation mode to meet different demands of using.
 
 

Fast DHW

You can select the Fast DHW Function for the unit to produce DHW when there is a need for immediate hot water production.
Product Tag:
Related categories:
Scroll to Top