Automatic Purge and Trap Instrument for Chromatography Mass Spectrometry Analysis

Min.Order: 1
Product origin: Wuxi, Jiangsu, China
Infringement complaint: complaintComplaint
US$ 1000 ~ 3000

Description
Automatic Purge And Trap Instrument
 
The FX-HSP-64A Automatic Purge and Trap Instrument is a fully automatic purge and trap instrument that integrates sampling, injection, and cleaning functions together. Liquid samples can be automatically and accurately sampled into a purge tube for purging and then analyzed through a trap. Solid samples can also be directly purged and collected after adding distilled water. It is widely used in environmental analysis such as the analysis of organic pollutants in drinking water, wastewater, and soil.
Standards

HJ639-2012 Water Quality - Determination of Volatile Organic Compounds - Purge Trap/Gas Chromatography, Mass Spectrometry,

HJ686-2014 Water Quality - Determination of Volatile Organic Compounds - Purge Trap/Gas Chromatography - Mass Spectrometry
HJ605-2011 Soil and Sediment - Determination of Volatile Organic Compounds - Purge Trap/Gas Chromatography - Mass Spectrometry. This product is a major national special support project of the company. 
 
Specifications

 

Sample bottleNumber of sample bottles: 64; Sample bottle volume: 40mL (37.5 * 100)
Purging pipeStandard purging pipe: 5mL filtered purging pipe (neck size 18mm);
Optional purging pipe: 25mL filtered purging pipe (neck size 18mm)
Trap trapStandard trap: 10 # (Tenax/silica gel/carbon molecular sieve);
Traps can be equipped first: 0 # (empty), 7 # (Tenax), 8 # (Tenax/silica gel), 9 # (Tenax/silica gel/charcoal)
Other Heat rate: ≤ 1800 ºC/min;
Cooling rate: 50 ºC/min, which can be cooled from 200 ºC to 30 ºC within 50 seconds;
Low cooling temperature: room temperature+1 ºC
Temperature rangeTrap trap: During the analysis and baking stages, the room temperature is up to 450 ºC (depending on the type of trap selected);
Water processor: room temperature+1 ºC to 270 ºC;
Temperature of six-way valve: room temperature+1 ºC to 350 ºC;
Sample bottle fixing temperature: room temperature+1 ºC to 200 ºC;
Transfer tube temperature: room temperature+1 ºC to 295 ºC
Time frame0.00 to 999min
Timing error <0.1%
Gas circuit withstand voltage0.4MPa
Cleaning times0 to 15 
communicationOutput start signal: Two independent external start signals can be output, which are triggered at the beginning of analysis;
Communication interface: RS232 serial port connection is adopted for communication between computers
Supply voltage220V±10% 50/60Hz
high-power800W